Affiliation:
1. Istituto Elettrotecnico Nazionale “Galileo Ferraris” - settore Acustica, Torino (Italy)
Abstract
This paper describes a procedure for evaluating the reduction in impact sound pressure level of floating floors by measuring the apparent dynamic stiffness of the resilient layer, according to International Standard EN 29052-1. The impact sound pressure level experimental data, obtained according to International Standard UNI EN ISO 140-8, was compared with estimates obtained from dynamic stiffness measurements. Results confirm the effectiveness of the empirical model. Two questions are addressed. The first concerns the decrease in layer thickness over time. The second concerns the relationship between damping ratio and performance.
Subject
Mechanical Engineering,Acoustics and Ultrasonics,Building and Construction
Cited by
30 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献