Affiliation:
1. Occupational and Environmental Medicine, the Sahlgrenska Academy at Goteborg University. Postal address: Box 414, 405 30 Gothenburg, Sweden
Abstract
This field study aimed to evaluate the prevalence of annoyance and disturbance and the subjective perception of the sound environment due to noise, in an old and a new control room at a large paper mill. Working in a control room requires sustained attention and concentration and, in the case of error messages, rapid and correct decisions. In this study, the personnel's responses were collected by questionnaire, and detailed sound measurements were taken in both control rooms. The A-weighted sound pressure level in the new control room was 54.9 dB, a reduction from the 63.5 dB measured in the old room, and the C-weighted sound pressure level was 66.8 dB, a reduction from the 75.2 dB measured in the old room. The new control room was rated as being a less noisy environment; however, the personnel did complain about noise from other computers/equipment, radios, and the new laboratory.
Subject
Mechanical Engineering,Geophysics,Mechanics of Materials,Acoustics and Ultrasonics,Building and Construction,Civil and Structural Engineering
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献