Affiliation:
1. Eskisehir Osmangazi University Department of Mechanical Engineering. Turkey First Air Supply and Maintenances Center. TUAF. Eskisehir. Turkey
Abstract
This paper presents the results of exergy and exergoeconomic analyses applied to a combined heat and power system with micro-gas turbine (MGTCHP). Quantative balances of the exergy and exergy cost for each component and for the whole system are carefully considered, while exergy consumption and cost generation within the system are determined. The exergy analysis indicates that the exergetic efficiency of the MGTCHP system is 35.80% with 123 kW (as 99.15 kW-electrical power and 24.46 kW-hot water@363.15 K). On the other hand, the exergoeconomic analysis results show that the unit exergy cost of electrical power and hot water produced by the MGTCHP system are accounted as 26.808 €(GW)−1 and 7.737 €(GW)−1, respectively.
Subject
Energy Engineering and Power Technology,Fuel Technology,Nuclear Energy and Engineering,Renewable Energy, Sustainability and the Environment
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献