Equivalence of the Bioimpedance and Thermodilution Methods in Measuring Cardiac Output in Hospitalized Patients With Advanced, Decompensated Chronic Heart Failure

Author:

Albert Nancy M.1,Hail Melanie D.1,Li Jianbo1,Young James B.1

Affiliation:

1. The Division of Nursing (NMA), George M. and Linda H. Kaufman Center for Heart Failure (MDH), Department of Biostatistics and Epidemiology (JL), and the Department of Cardiovascular Medicine (JBY), Cleveland Clinic Foundation, Cleveland, Ohio.

Abstract

• Background An accurate and reliable noninvasive method for determining cardiac output/cardiac index would be valuable for patients with acutely decompensated advanced systolic heart failure.• Objectives To determine whether a correlation exists for cardiac output and index determined by using bioimpedance and thermodilution in patients with acutely decompensated complex heart failure and if differences between results with the 2 methods could be explained by the patients’ advanced condition.• Methods Cardiac output and index were determined by using bioimpedance and thermodilution in 33 patients. Echocardiographic and electrocardiographic data were assessed to determine if differences between results with the 2 methods could be explained by the patients’ advanced condition. Concordance correlation coefficients and Bland-Altman agreement between methods were calculated.• Results Four patients were excluded from analysis because reliable measurements could not be obtained; the remaining 29 patients constituted the study population. Mean cardiac outputs determined by thermodilution and bioimpedance were 5.48 and 5.40 L/min, respectively (ρc =0.89, P < .001), and mean cardiac indexes were 2.67 and 2.65 (ρc = 0.82, P < .001). Mean bias (limits of agreement) between data pairs was 0.08 (−0.18 to 0.35) L/min (P = .52) for cardiac output and 0.03 (−0.097 to 0.16; P = .61) for cardiac index. Six data pairs (21%) had an absolute percent difference greater than 15%. Of these, 50% had a higher thermodilution value.• Conclusion Determinations of cardiac output and index by both methods were significantly correlated. Mean bias between the 2 methods was small, suggesting clinical utility for bioimpedance in patients with complex decompensated heart failure.

Publisher

AACN Publishing

Subject

Critical Care Nursing,General Medicine

Cited by 108 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3