Accuracy of infrared ear thermometry and other temperature methods in adults

Author:

Erickson RS,Meyer LT

Abstract

OBJECTIVE: To compare the accuracy of infrared ear-based temperature measurement in relation to thermometer, ear position, and other temperature methods, with pulmonary artery temperature as the reference. METHODS: Ear-based temperature measurements were made with four infrared thermometers, three in the core mode and two in the unadjusted mode, each with tug and no-tug techniques. Pulmonary artery, bladder (n = 21), and axillary temperatures were read after each ear-based measurement and oral temperature was measured once when possible (n = 32). Subjects consisted of a convenience sample of 50 patients with pulmonary artery catheters who were in adult critical care units of a university teaching hospital. RESULTS: Ear-based measurements correlated well with pulmonary artery temperature (r = .87 to .91), although closeness of agreement differed among thermometer-mode combinations (mean offsets = -0.7 to 0.5 degree C) and had moderately high variability between subjects (SD = +/- 0.5 degree C) with all instruments. Use of an ear tug either made no difference or resulted in slightly lower readings. Bladder temperature was nearly identical to pulmonary artery temperature values (r = .99, offset = 0.0 +/- 0.2 degree C). Oral readings were slightly lower (r = .78, offset = -0.2 degree C) and axillary readings much more so (r = .80 to .82, offset = -0.7 degree C); both were highly variable (SD = +/- 0.6 degree C) and affected by external factors. CONCLUSIONS: Infrared ear thermometry is useful for clinical temperature measurement as long as moderately high variability between patients is acceptable. Readings differ among thermometers, although several instruments provide values close to pulmonary artery temperature in adults. Readings are not higher with an ear tug. Bladder temperature substitutes well for pulmonary artery temperature, whereas oral and axillary values may be influenced by external factors in the critical care setting.

Publisher

AACN Publishing

Subject

Critical Care,General Medicine

Cited by 64 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3