Using a Standardized Rounding Tool to Improve the Incidence of Spontaneous Awakening and Breathing Trials

Author:

Lancaster Billie1,Shifrin Megan M.2,Gast Sarah3

Affiliation:

1. Billie Lancaster is an adult-gerontology acute care nurse practitioner in the medical intensive care unit at Saint Thomas West Hospital, Nashville, Tennessee.

2. Megan M. Shifrin is an associate professor of nursing at Vanderbilt University School of Nursing, Nashville, Tennessee, and serves as the Intensivist AGACNP Focus Coordinator.

3. Sarah Gast is an assistant professor at Vanderbilt University School of Nursing.

Abstract

Background Spontaneous awakening and breathing trials have been associated with shorter durations of mechanical ventilation and intensive care unit lengths of stay. Local Problem Inconsistent spontaneous awakening trials and spontaneous breathing trials, mechanical ventilation weaning strategies, and interdisciplinary rounding processes contributed to prolonged mechanical ventilation duration and length of stay in a 44-bed adult medical intensive care unit. Methods A standardized rounding tool that focused on coordinating spontaneous awakening and breathing trials, and on their outcomes, was integrated into daily multidisciplinary rounds in a medical intensive care unit. Aggregated patient data from the 4-month project implementation phase were compared with historical data collected for 2 months before project implementation. Results During the 2-month preintervention phase, 613 adult patients were managed in the medical intensive care unit and 41 patients required mechanical ventilation, whereas during the 4-month intervention phase, 1271 patients were managed in the unit and 96 patients required mechanical ventilation. The project was associated with a 24% (0.89-day) reduction in the mean length of stay (3.72 vs 2.83 days) and a 46.3% (2.81 day) reduction in mechanical ventilation duration (6.06 vs 3.25 days) when comparing August 2019 to January 2020. Discussion A standardized rounding tool emphasizing a coordinated process for spontaneous awakening and breathing trials was associated with a shorter length of stay and duration of mechanical ventilation among patients in the medical intensive care unit. Conclusion An evidence-based approach to weaning from mechanical ventilation and standardized rounding may be a cost-effective way to reduce mechanical ventilation duration and length of stay in a medical intensive care unit.

Publisher

AACN Publishing

Subject

Critical Care Nursing,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3