Author:
Konopad E,Grace M,Johnston R,Noseworthy T,Shustack A
Abstract
BACKGROUND: Blood samples obtained through heparinized arterial catheters are used routinely for a variety of laboratory tests. Accuracy of coagulation studies performed from samples obtained in this fashion continues to be questioned, particularly in regard to the minimum discard volume necessary to clear the catheter of heparinized solution. OBJECTIVE: To examine differences between prothrombin time and activated partial thromboplastin time values obtained from blood drawn by venipuncture and from an indwelling intra-arterial line using three discard volumes. METHODS: Prothrombin time and activated partial thromboplastin time samples were drawn by venipuncture from 41 critically ill adult patients. Simultaneously, three consecutive blood samples of 2.3 mL were drawn from the arterial line after an initial discard volume of 3 mL (discard volumes of 3.0, 5.3 and 7.6 mL). RESULTS: Significant differences were found between arterial and venous prothrombin time values for the 3-mL discard volume group, as well as between arterial and venous activated partial thromboplastin time values for all three discard volume groups (paired t-test, Bonferroni correction). CONCLUSION: We recommend that when drawing prothrombin time and activated partial thromboplastin time samples from an arterial line, a 5.3-mL discard volume be used.
Subject
Critical Care Nursing,General Medicine
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献