Affiliation:
1. Department of Athletic Training, Lynchburg College, VA
2. Department of Athletic Training, Seton Hall University, South Orange, NJ
3. Department of Physical Therapy and Athletic Training, Northern Arizona University, Flagstaff
Abstract
Context:
Patient ventilation volume and rate have been found to be compromised due to the inability to seal a pocket mask over the chinstrap of football helmets. The effects of supraglottic airway devices such as the King LT and of lacrosse helmets on these measures have not been studied.
Objective:
To assess the effects of different airway management devices and helmet conditions on producing quality ventilations while performing cardiopulmonary resuscitation on simulation manikins.
Design:
Crossover study.
Setting:
Simulation laboratory.
Patients or Other Participants:
Thirty-six athletic trainers (12 men, 24 women) completed this study.
Intervention(s):
Airway-management device (pocket mask, oral pharyngeal airway, King LT airway [KA]) and helmet condition (no helmet, Cascade helmet, Schutt helmet, Warrior helmet) served as the independent variables. Participant pairs performed 2 minutes of 2-rescuer cardiopulmonary resuscitation under 12 trial conditions.
Main Outcome Measure(s):
Ventilation volume (mL), ventilation rate (ventilations/min), rating of perceived difficulty (RPD), and percentage of quality ventilations were the dependent variables.
Results:
A significant interaction was found between type of airway-management device and helmet condition on ventilation volume and rate (F12,408 = 2.902, P < .0001). In addition, a significant interaction was noted between airway-management device and helmet condition on RPD scores (F6,204 = 3.366, P = .003). The no-helmet condition produced a higher percentage of quality ventilations compared with the helmet conditions (P ≤ .003). Also, the percentage of quality ventilations differed, and the KA outperformed each of the other devices (P ≤ .029).
Conclusions:
The helmet chinstrap inhibited quality ventilation (rate and volume) in airway procedures that required the mask to be sealed on the face. However, the KA allowed quality ventilation in patients wearing a helmet with the chinstrap fastened. If a KA is not available, the helmet may need to be removed to provide quality ventilations.
Publisher
Journal of Athletic Training/NATA
Subject
Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,General Medicine
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献