Dexamethasone Sodium Phosphate Penetration During Phonophoresis at 2 Ultrasound Frequencies

Author:

Rigby Justin H.1,Hagan Austin M.2,Kelcher Austin R.2,Ji Chang2

Affiliation:

1. University of Utah, Salt Lake City

2. Texas State University, San Marcos

Abstract

Context The effect of ultrasound frequency on phonophoresis drug delivery in humans is unknown. Objective To determine if a low (45-kHz) or high (1-MHz) frequency delivered a higher dexamethasone (Dex) concentration through the skin. Design Controlled laboratory study. Setting Laboratory. Patients or Other Participants A total of 40 healthy men between the ages of 18 and 45 years (age = 23.1 ± 2.6 years, height = 176.1 ± 7.2 cm, mass = 88.5 ± 19.4 kg, posterior calf subcutaneous thickness measured using musculoskeletal ultrasound imaging = 0.6 ± 0.2 cm). Intervention(s) Participants were randomly assigned to 1 of 4 groups (ultrasound frequency at microdialysis probe depth): (1) 45-kHz frequency at 1 mm, (2) 45-kHz frequency at 4 mm, (3) 1-MHz frequency at 1 mm, or (4) 1-MHz frequency at 4 mm (n = 10 in each group). Three linear microdialysis probes were inserted at the desired tissue depth. We rubbed dexamethasone sodium phosphate (Dex-P) into the skin and then applied a 15-minute phonophoresis treatment. Main Outcome Measure(s) Dialysate was collected during the treatment and 60 minutes posttreatment and analyzed for Dex-P, Dex, and the metabolite form of Dex. The sum of the 3 analytes was calculated as total dexamethasone (Dex-total), and differences between the 45-kHz and 1-MHz treatment groups were determined by a repeated-measures analysis of variance. Results At 1 mm, 3 (30%) participants in the 45-kHz and 4 (40%) participants in the 1-MHz group had measurable levels of Dex-P. Total dexamethasone increased after the treatment ceased, independent of ultrasound frequency (P < .001), with a trend of the 45-kHz treatment to produce a greater increase in drug concentration (P = .006). At 4 mm, 5 (50%) participants in the 45-kHz and 1 (10%) participant in the 1-MHz group had measurable levels of Dex-P. We observed no difference in Dex-total concentration between treatment groups at 4 mm (P = .72). Conclusions Phonophoresis provided a mechanism for Dex-total delivery at the 1- and 4-mm tissue depths. However, the effectiveness of the ultrasound frequencies varied between the 2 measured tissue depths.

Publisher

Journal of Athletic Training/NATA

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3