Liver Functional Evaluation Using Gadoxetic Acid Versus the Gold Standard Hepatobiliary Scintigraphy in Patients with Bile Duct Diseases

Author:

Shorikov M. A.1ORCID,Sergeeva O. N.1ORCID,Kashkadaeva A. V.1ORCID,Averinova S. G.1ORCID,Lapteva M. G.1ORCID,Frantsev D. Yu.1ORCID,Polyakov A. N.1ORCID,Kudashkin N. E.1ORCID,Alekhin A. P.1ORCID,Moroz E. A.1ORCID,Virshke E. R.1ORCID,Dolgushin B. I.1ORCID

Affiliation:

1. N.N. Blokhin National Medical Research Center of Oncology, Ministry of Health of the Russian Federation

Abstract

Objective. To compare liver function assessments using Gd-EOB-DTPA-enhanced MRI and the gold standard hepatobiliary scintigraphy (HBS) in patients with bile duct diseases.Material and methods. The investigation enrolled 18 patients (male/female = 11/7; age, 29–70 years, Klatskin tumor (n=16), bile duct epithelial dysplasia (n=1), intrahepatic cholangiolithiasis (n=1)) after biliary decompression, who underwent 21 paired MRIs and 99mTc-mebrofenin HBS at a study interval of no more than 3 days. In the same regions of interest with a size of 30–50 pixels located in liver segments II–III, IV, V–VIII, and VI–VII, a MRI signal was measured before MR contrast agent (MRCA) injection into the standard vascular phases and at 10, 20, 30 and 40 minutes, then the signal was expressed as a percentage of intensity compared to the precontrast series. After MR volumetry, the functional volumes of the left and right liver lobes were also defined as the area under the MRCA accumulation curve, which was multiplied by the lobe volume and expressed as a percentage of the similarly calculated function of the entire liver. Similar intensity parameters and functional volumes were estimated for a HBS study.Results. The lobe functional volumes measured by the two methods were highly correlated (R=0.8; p<0.001) and did not show a significant difference at all when comparing with the Mann–Whitney test (p>0.3). The excretion rate of 99mTc-mebrofenin was also highly correlated with MRI findings (R=0.5–0.9; p<0.05). Conclusion. Gd-EOB-DTPA-enhanced MRI revealed a high correlation with the gold standard; however, additional studies are needed to clarify the possibilities and limitations of replacing one method with another one.><0.05).Conclusion. Gd-EOB-DTPA-enhanced MRI revealed a high correlation with the gold standard; however, additional studies are needed to clarify the possibilities and limitations of replacing one method with another one.

Publisher

Luchevaya Diagnostika

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The system for assessing liver function according to magnetic resonance imaging with gadoxetic acid;The Siberian Journal of Clinical and Experimental Medicine;2022-07-15

2. Magnetic resonance imaging in liver function analysis. Modern objective reality;Khirurgiya. Zhurnal im. N.I. Pirogova;2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3