Abstract
In the present work we found the maximum discovery distance for 239Pu-Be source using the detectors based on ZWO (ZnWO4) and BGO (Bi4Ge3O12) oxide scintillators. Detection distance was defined by using the radiation monitoring system ”PORTAL”. This research gives us data for estimation of the contribution of low-energy cascade gamma quanta CGQ. The CGQ emitted by excited scintillator nuclei defined the effective discovery distance of the fast neutrons source. The maximum detection distance was obtained with PMT in a single-photon counting mode. The maximum discovery distance for a BGO scintillator of size Ø40×40 mm – 38 cm, ZWO scintillator of size Ø52×40 mm – 54 cm, with reliability about 0.001. The results of the experiment on the ZWO scintillator can be explained by the registration of additional gamma quanta from the inelastic scattering reaction and the CGQ arising from resonant neutron capture region. This two mechanisms further lead to increase the sensitivity of the detector and increase the detection distance of the monitoring system. The key features of the monitoring system are: ZWO oxide scintillator, wide band measuring path, utilize PMT in single photon mode. The obtained detection distance was about 1.4 times higher in comparison with the spectrometric recording mode and 1.9 times higher in values of efficiency. Our results demonstrate the advantages of the ZWO scintillator compared to the BGO and demonstrate the possibility of using the resonant capture mechanism by ZWO detector nuclei to increase the fast neutrons sensitivity. The resonance capture mechanism increase sensitivity and maximum detection distance of the monitoring system. The low-energy gamma-quanta, which discharge of compound nuclei, are substantially suppressed in comparison with the classic spectrometric recording mode.
Publisher
V. N. Karazin Kharkiv National University
Subject
General Physics and Astronomy,General Materials Science
Reference10 articles.
1. M. Anellia, G. Battistoni, S. Bertolucci, C. Bini, P. Branchini, C. Curceanu, G. De Zorzi et al., Nucl. Inst. Meth. Phys. Res. A, 580, 368-372 (2007), https://doi.org/10.1016/j.nima.2007.08.005.
2. L.L. Nagornaya, V.D. Ryzhikov, B.V. Grinyov, L.A. Piven’, G.M. Onyshchenko and E.K. Lysetska, in: Abstracts IEEE Nuclear Science Symposium, (Drezden, Germany, 2008), pp. 714-719. https://doi.org/10.1109/NSSMIC.2008.4775229.
3. B. Grynyov, V. Ryzhikov, L. Nagornaya, G. Onishcenko, L. Piven’. US Patent No. 8058624 (15 November 2011), http://patft.uspto.gov/netacgi/nph-Parser?Sect1=PTO2&Sect2=HITOFF&p=1&u=%2Fnetahtml%2FPTO%2Fsearch-adv.htm&r=1&f=G&l=50&d=PTXT&S1=(%228058624%22.PN.)&OS=PN/.
4. V.D. Ryzhikov, B.V. Grinyov, G.M. Onyshchenko, L.A. Piven, O.K. Lysetska, O.D. Opolonin, S.A. Kostioukevitch and C.F. Smith, in: XVI SPIE Optical Engineering Proceedings, “Hard X-Ray, Gamma-Ray, and Neutron Detector Physics”, (IEEE, San Diego, 2014), https://doi.org/110.1117/12.2058185.
5. V.D. Ryzhikov, S.V. Naydenov, G.M. Onyshchenko, L.A. Piven, T. Pochet and C.F. Smith, Nucl. Inst. Meth. Phys. Res. A, 903, 287–296 (2018), https://doi.org/10.1016/j.nima.2018.06.074.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献