Total Knee Arthroplasty: The Impact of Tourniquet Usage on Cement Penetration, Operation Time, and Bleeding Control

Author:

Peker GökhanORCID,Altun İbrahimORCID

Abstract

Objective: The cementing technique employed in total knee arthroplasty (TKA) significantly influences the penetration of cement into the bone, ultimately affecting the stability of the joint. This study aimed to assess the impact of tourniquet usage on tibial cement penetration, operative time, bleeding, and functional outcomes following TKA. Materials and Methods: A retrospective evaluation was conducted on 103 patients who had undergone TKA and had a minimum follow-up period of 2 years. The patients were categorized into three groups: Group 1 utilized a tourniquet throughout the entire surgery, Group 2 released the tourniquet immediately after prosthesis implantation, just before cement hardening, and Group 3 did not employ a tourniquet at any stage of the procedure. Tibial cement penetration was assessed via X-ray examination, following the Knee Society Scoring System criteria. Operative time, bleeding levels, and Lysholm and Oxford scores were compared among the groups. Statistical analysis was performed using SPSS version 22.0 software. Results: In Group 1, bone penetration of cement was significantly higher than in both Group 2 and Group 3, except for zone 1 in the anterior-posterior (AP) view (p < 0.017). Group 3 exhibited significantly less bleeding compared to the other groups (p < 0.017). There was no significant difference in terms of bleeding between Group 1 and Group 2. The operation time was significantly shorter in Group 1 compared to the other groups (p < 0.017). The mean cement penetration depth across all groups was measured at 2.44 ± 0.27 mm. Bleeding volume and operation time did not have a significant effect on mean cement penetration (p > 0.05). Additionally, there were no significant differences observed between the groups in terms of the Lysholm and Oxford functional test results (p > 0.017). Conclusions: The use of a tourniquet was found to increase cement penetration and reduce operation time; however, it did not have a significant impact on reducing bleeding. Based on our findings, we recommend considering a shorter tourniquet time and implementing effective bleeding control measures to mitigate potential complications associated with tourniquet usage.

Publisher

Lycia Press London UK

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3