Quantitative Nondispersive X-Ray Fluorescence Analysis of Highly Radioactive Samples for Uranium and Plutonium Concentration *

Author:

Pickles W. L.,Cate J. L.

Abstract

AbstractFluorescent x-ray energy spectra were successfully acquired from uranium and plutonium in 400:1 ratios in samples containing 2 Ci/gram of mixed fission products. The analytical system consists of a silver transmission anode x-ray tube, a low-Z scattering chamber, a magnetic ß-ray trap, a beam monitor probe, a commercial Si(Li) detector, a set of modified electronics to handle the large γ-ray overload rate, and a Computer analyzer using a higher-level language to handle data reduction.The Computer programs used to obtain peak areas from the closely spaced uranium and plutonium (Lα 1+2) peaks were constructed to make use of knowledge of upper-edge tailing gained in this experiment. Programs are being developed to properly remove background under the uranium and plutonium peaks. Absorption effects in the larger samples have been measured using the ratio of uranium (Lℓ) to uranium (Lα) peak area and are incorporated in the data-analysis schemes. A titanium monitor probe, consisting of a fixed titanium plate near the sample, introduces a constant-area titanium K x-ray line into the spectrum. The program uses the area of this peak to correct for effects of total exciting flux, geometry, and system dead-time losses. Standard samples of various types are used to generate calibration curves from which quantitative results are obtained.Samples are taken from dissolved high-burnup power-reactor fuel rods. The liquid sample is acidic and has a radiation level at one foot of approximately 2 R/hr ß and 300 mR/hr γ. Sample preparation involves only the evaporation of the liquid sample on a 1/2-mil polycarbonate substrate and subsequent sealing with another layer of polycarbonate film. The samples are then mounted in standard 35-mm slide-holders.Preliminary testing on a limited number of prepared uranium and plutonium samples indicates a precision of about 1% and an accuracy of about 2%, over a range of 1 to 58 μg total mass. The samples have not yet been verified by independent chemical analysis. The system has been installed at the AEC Savannah River facility for extensive testing.

Publisher

Cambridge University Press (CUP)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. X-Ray Fluorescence Experiments with Polarized X Rays;Advances in X-Ray Analysis;1975

2. X-Ray Fluorescence Experiments with Polarized X-Rays*;Advances in X-ray Analysis;1974

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3