State Primary Standard of Gas Volume and Flow Rate Units for the Pressure Range of 1 MPa to 5 MPa (PVTt-15)

Author:

Rozhnov M. S.,Kuzmenko Yu. V.,Melnyk D. M.,Levbarg O. S.,Rak A. M.,Pashun V. I.,Pohribna L. M.

Abstract

For the first time in Ukraine a primary measurement standard of gas volume and flow rate units in a pressure range of 1 MPa to 5 MPa has been created. The standard is based on realisation of the units by PVTt principle and units dissemination using critical Venturi nozzles. Gas passing through the nozzle during its calibration fills an evacuated collection tank located downstream the nozzle, and the respective time interval is measured. Mass flow rate is calculated by multiplying the volume of the collection tank by the gas density change and dividing by the tank filling time. Density values are determined by the equation of state and the measured initial and final pressure and temperature values. The structural and functional scheme of the measurement standard is shown in Figure 3. The standard consists of two units. The first unit is intended to realise, keep and transfer the units of gas volume and flow rate. The general view of the block is shown in Figure 4. The unit contains high pressure collection tank, precision water thermostat, vacuum pump, piston gas pressure gauge, flow switch, fine filter, a set of seven Venturi nozzles with diameters from 0.1 mm to 3.0 mm. The second unit is designed to form a stationary gas flow and provide a critical gas flow rate (at the speed of sound) at the nozzle throat. In the case of an elementary reversible adiabatic (isoentropic) process at a critical velocity, the mass flow rate of gas passing through the nozzle is maximally possible. The unit consists of equipment for reducing the pressure from 150 bar to 70 bar and from 70 bar to 10 bar, the heat exchanger and the instruments measuring the pressure and temperature of the gas flow. The created measurement standard will assure metrological traceability of the measurements of gas volume and volume flow rate at high pressures for the flow rate up to 100 m3/h and calibration of the primary reference nozzles with a throat diameter from 0.1 mm to 3 mm.

Publisher

SE Ukrmetrteststandart

Subject

Microbiology (medical),Immunology,Immunology and Allergy

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3