Comparison of Osteotomy Level with Three Different Canine Total Hip Replacement Systems

Author:

Franklin Samuel,Franklin Ashley,Feyerabend Nathan,Hayashi Kei,Miller Nathan,Cook James

Abstract

Background: Numerous cementless total hip replacement systems are available for application in dogs and one of the potential differences among these systems is the technique for performing a femoral osteotomy and the amount of bone preserved in the calcar region. However, no quantitative comparison of osteotomy level has been performed for canine THRs to date. Objectives: 1) To develop and validate a method for quantifying the level of the osteotomy at its most distomedial aspect in conjunction with canine total hip replacement (THR) and 2) to compare osteotomy level between multiple different THRs. Methods: Immediate post-operative cranial-caudal or caudal-cranial radiographs of 33 dogs treated with 17 Helica and 17 BFX THR were assessed and osteotomy level was quantified using a novel radiographic assessment by 3 independent observers. Correlation among observers was quantified using a Spearman rank order correlation. Osteotomy location was subsequently quantified for an additional 10 Zurich THRs. The osteotomy level for each THR was subsequently compared between Helica, BFX, and Zurich THRs using one-way non-parametric Mann-Whitney rank sum tests and significance set at p<0.05. Results: R-values assessing correlation between observers were 0.87, 0.72, and 0.60. Osteotomy location was significantly more proximal in conjunction with the Helica (0.75 ± 0.22) versus the BFX (0.97 ± 0.13; p<0.001) and Zurich (1.1, ±0.15; p<0.001) femoral prostheses. Osteotomy location was also significantly more proximal with the BFX prosthesis in comparison to the Zurich THR (p<0.05). Conclusion: The strong correlations among three different observers indicates that the technique for measuring the location of the distomedial aspect of the osteotomy was acceptably precise. The osteotomies made in conjunction with the short-stemmed Helica implants were significantly more proximal than those made with both of the long-stemmed (BFX and Zurich) femoral prostheses. The distomedial aspect of the osteotomy with the BFX system was significantly more proximal than that with the Zurich THR, indicating that between these two long-stemmed systems the osteotomy level is unique.

Publisher

ScopeMed

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3