Physical and chemical changes of clear aligners after thermoforming and intraoral exposure

Author:

Dalaie Kazem1,Rafsanjan Katayoun Talebi1,Nojehdehian Hanieh2,Namazi Zahra2

Affiliation:

1. Department of Orthodontics, Shahid Beheshti University of Medical Sciences, Tehran, Iran,

2. Department of Dental Biomaterials, Shahid Beheshti University of Medical Sciences, Tehran, Iran,

Abstract

Objectives: This study assessed the physical and chemical changes of clear aligners after thermoforming and intraoral exposure. Material and Methods: This ex vivo study evaluated raw sheets, thermoformed sheets, and aligners used for 2 weeks from two commercial brands of Erkodur and Shinseki (n = 8 in each group). The surface hardness (by the Vickers hardness test), thickness (by a digital caliper), and glass transition temperature (Tg) (by differential scanning calorimetry) of the specimens were measured, and they underwent X-ray diffraction (XRD) to assess their degree of crystallinity and attenuated total reflectance-Fourier-transform infrared spectroscopy (ATR-FTIR) for analysis of their molecular composition. Data were analyzed by one-sample, paired and independent t-tests, and Mann–Whitney U and Wilcoxon signed-rank tests (alpha = 0.05). Results: The XRD and ATR-FTIR spectra of Erkodur and Shinseki aligners matched those of polyethylene terephthalate glycol polymer and did not change after thermoforming or intraoral exposure. Unlike intraoral exposure (P > 0.05), thermoforming significantly decreased the hardness of both brands of aligners (P < 0.05). Intraoral exposure significantly decreased the thickness of Erkodur aligners at some points and significantly increased the thickness of Shinseki aligners (P < 0.05). Thermoforming significantly decreased the Tg of both brands of aligners (P < 0.05). Intraoral exposure significantly decreased the Tg of Erkodur and increased the Tg of Shinseki aligners (P = 0.000). Conclusion: Erkodur and Shinseki aligners showed high chemical and structural stability after thermoforming and 2 weeks of intraoral exposure. However, thermoforming affected the thermal and physical properties of both brands of aligners. Erkodur aligners had higher dimensional stability than Shinseki aligners.

Publisher

Scientific Scholar

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3