Arteriovenous shunt status post-coronary artery bypass graft surgery treated with microcoil placement: A case report

Author:

Reick-Mitrisin Victoria1,Mohan Jay2,Stenz Justin3,Zainea Mark4

Affiliation:

1. Department of Education, A.T. Still University-Kirksville College of Osteopathic Medicine, Kirksville, Missouri,

2. Department of Cardiology, McLaren Macomb, Mount Clemens, Roseville, Michigan, United States,

3. Department of Interventional Radiology, McLaren Macomb, Mount Clemens, Roseville, Michigan, United States,

4. Department of Cardiology, Cardiology Associates of Michigan, Roseville, Michigan, United States,

Abstract

Accidental cardiac arteriovenous (AV) anastomoses is a rare but severe complication of coronary artery bypass grafting. This can result in high output heart failure if left untreated. Little research has been done on the mainstays of treatment for this condition. Our patient is an 82-year-old male with a history of known coronary artery disease, status post-coronary bypass grafting surgery, presented with increasing shortness of breath, which was initially determined clinically to be due to high output heart failure, which was later confirmed during cardiac catheterization procedure. Coronary cardiac catheterization was carried out 2 weeks prior at an outside hospital for which the graft, which is supposed to be anastomosed of the circumflex, inadvertently anastomosed to the coronary sinus. The patient returned to the cardiac catheter lab and repeat angiography was performed. The left to right shunt was subsequently embolized using microcoils. He tolerated the procedure well. No recurrent anginal and/or heart failure symptoms were present. Interventional cardiology began the procedure by gaining right common femoral access. Next the saphenous vein graft to the coronary sinus was engaged with a 6 French JRy (Medtronic Inc., Minneapolis, MN) guide catheter and a 0.014” coronary wire was placed into the graft. Then interventional radiology advanced a 2.4 French microcatheter (Terumo, Ann Arbor, MI USA) over the 0.014” wire (Abbott Vascular Devices, Plymouth MN) into the mid to distal aspect of the bypass graft. Four detachable 0.018” microcoils (Terumo, Ann Arbor, MI USA) were carefully placed within the bypass graft. Subsequent angiogram demonstrated complete occlusion of the bypass graft with resolution of the AV shunt. Due to the acuity of the patient’s symptoms and the long timeframe from originally attempting stenting, no additional attempts to stent the circumflex were performed. Follow-up angiogram through the base catheter demonstrates complete occlusion of the bypass graft with resolution of the AV shunt. No contrast was seen entering the coronary sinus. The patient tolerated the procedure well with no immediate complications. Estimated blood loss was <10 mL. The patient was admitted overnight for further evaluation. No shortness of breath noted. He was discharged in good condition the following day. Accidental cardiac AV anastomosis is a rare complication of coronary artery bypass grafting that could lead to high output heart failure. In such cases, catheter directed embolization with microcoils can be done to occlude the AV shunt created by the previously placed cardiac catheter with resolution of heart failure symptoms.

Publisher

Scientific Scholar

Subject

Computer Networks and Communications,Hardware and Architecture,Software

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3