Assessment of radiation equivalent dose to pediatric patients during chest radiography

Author:

Inah Grace Ben1,Ukpong Ekaete V.2,Esien-Umo Emmanuel O.2,Ibe Blessing2,Ijever Andrew W.2,Erim Akwa Egom2,Paulinus Samson O.2

Affiliation:

1. Department of Radiology, University of Calabar Teaching Hospital, Cross River State, Nigeria,

2. Department of Radiography and Radiological Science, University of Calabar, Calabar, Cross River State, Nigeria,

Abstract

Objectives: The study investigated the equivalent dose delivered during pediatric chest radiography. Material and Methods: This study adopted a prospective and cross-sectional research design and was conducted between April 26 and July 2, 2021, at the University of Calabar Teaching Hospital, Calabar, Cross river state, Nigeria. A total of 85 pediatric patients aged 0–15 years, referred for chest X-ray examination, were recruited into the study. The chest radiography was taken for each child in erect or supine positions. Children, who needed some form of immobilization, were immobilized and respiration (breathing) was observed to take exposures at end-expiration. Exposure factors used ranged between 40 and 80 kVp, 1–2 mAs, source-to-image distance; 110 cm. Patient demographics and chest X-ray exposure factors for each exposure were recorded using a spreadsheet. The equivalent dose was calculated using the NUTECHRX software version. All statistical analyses were performed using the Statistical Package for the Social Sciences (SPSS) version 21.0. Statistical significance was set at P < 0.05. Results: The estimated mean equivalent dose was 0.0046 ± 0.0026 mSv, while the mean of weight (kg), kVp, and mAs was 15.04 ± 14.51 kg, 58.28 ± 10.58V, and 1.79 ± 1.56 mAs, respectively. Mean equivalent dose was 0.00447mSv (uncertainty 0.0027) for female and 0.00464mSv (uncertainty 0.0026) for male, with no significance difference between them. The mAs showed strong positive correlation with equivalent dose (r = 0.71, P = 0.05), while weight demonstrated a strong negative correlation with equivalent dose (r = −0.98, P = 0.05). Conclusion: Current-time product (mAs) and the weight of a child are important determinants of equivalent dose in pediatric chest radiography.

Publisher

Scientific Scholar

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3