Ergonomics of surgical microscopes for the sitting position as determined by ocular-corpus length

Author:

Goehre Felix1,Ludtka Christopher2,Schwan Stefan3

Affiliation:

1. Department of Neurosurgery, Stroke Center, Bergmannstrost Hospital Halle, Halle, Saxony-Anhalt, Germany,

2. Department of Biomedical Engineering, University of Florida, Gainesville, Florida, United States,

3. Department of Design and Prototyping, Fraunhofer Institute for Microstructure of Materials and Systems, Halle, Saxony-Anhalt, Germany.

Abstract

Background: The sitting position is favorable for microsurgical procedures applied to posterior midline pathologies in both the supra- and infratentorial regions. The dimensions of the microscope corpus affect the device’s comfort and handling in the hands of the microneurosurgeon for such procedures. A shorter microscope corpus provides more favorable intraoperative ergonomics for surgical practice. Methods: Evaluation of the most comfortable microscope for its application in microsurgical procedures in the sitting position as determined by ocular-corpus length. Results: Six modern surgical microscopes were tested and evaluated regarding their ocular-corpus lengths and working distances: the Mitaka MM90, Zeiss Kinevo 900, Zeiss Pentero 900, Leica M530, Zeiss Neuro NC4, and Möller-Wedel Hi-R 1000. The ocular-corpus lengths vary between 270 and 380 mm. The Mitaka MM90 microscope has the shortest ocular-corpus length at 270 mm. Conclusion: The ocular-corpus length determines the predominant part of the lever arm, which affects the fatigue of the surgeon. By virtue of its short ocular-corpus length, the Mitaka MM90 is currently the most favorable microscope for microsurgical procedures using a sitting position.

Publisher

Scientific Scholar

Subject

Clinical Neurology,Surgery

Reference10 articles.

1. Antropologischer Atlas;Flügel,1986

2. Microsurgical management of pineal region lesions: Personal experience with 119 patients;Hernesniemi;Surg Neurol,2008

3. Measurement of physical work capacity during arm and shoulder lifting at various shoulder flexion and ad/abduction angles;Kim;Hum Factors Ergon Manuf,2003

4. Infratentorial supracerebellar approach to the colloid cysts of the third ventricle;Konovalov;Neurosurgery,2001

5. Principles of treatment of the pineal region tumors;Konovalov;Surg Neurol,2003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3