Radiologically inserted gastrostomy tube in neurological disease: A retrospective study

Author:

Zaita Brittany Marie1,Ghosh Abheek2,Lee Sean1,Raymond Aislynn2,Agnihotri Tanvir3,Akhter Nabeel M.4

Affiliation:

1. Department of Biomedical Science, Touro College of Osteopathic Medicine, Middletown, United States,

2. Department of Interventional Radiology, University of Maryland School of Medicine, Baltimore, United States,

3. Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, United States,

4. Department of Radiology, Mercy Medical Center, Baltimore, United States,

Abstract

Objectives: This study aimed to compare the safety and efficacy of balloon and non-balloon (or dilator) gastrostomy devices in radiologically inserted gastrostomy (RIG) for patients with neurological disease. Material and Methods: A retrospective analysis of 152 patients was conducted at a tertiary care hospital from July 2017 to September 2020. 104 and 48 patients were included in the balloon and non-balloon groups, respectively. The frequency of complications per specific neurological indication as well as the breakdown of the different complications pertaining to each indication was recorded for analysis. The recovery time, fluoroscopy time, contrast volume, peak radiation, and pain management dosages for each procedure were all reviewed to evaluate for statistical differences between the balloon and non-balloon groups. An adjusted model odds ratio (OR) was conducted to evaluate how each of the variables (type of gastrostomy tube, body mass index [BMI], age, and gender) affected the frequency of complications within our cohort. Results: This study included 152 patients, with an average age of 65.17 years (interquartile range [IQR] = 12.66) and an average BMI of 26.97 (IQR = 7.19). The majority of patients were male (71.1%). The most common indication for the procedure was stroke (24.3%), followed by post-intubation dysphagia (16.4%) and intracranial hemorrhage (11.8%). Amyotrophic lateral sclerosis (ALS) and altered mental status had a similar prevalence at 9.9%. The overall complication rate was 33.8%, overall mortality rate 3.3%, 30-day mortality rate of 2.6%, and no other major complications according to CIRSE criteria. Notably, patients with neurodegenerative disorders exhibited comparable rates of minor complications: 33.3% in ALS (5/15 patients), 50% in myasthenia gravis (1/2 patients), and 100% in muscular dystrophy (1/1 patient). The study compared two groups: the balloon group (104 patients) and the dilator group (48 patients). The balloon group received significantly lower preoperative sedation in the form of fentanyl (Avg = 4.46 min vs. 6.54 min, P = 0.287). The balloon group had shorter fluoroscopy time, lower radiation exposure dose, and shorter operating time compared to the dilator group, though not statistically significant. In the logistic regression model, there was no statistical difference in complication rates between the dilator and balloon groups. BMI, age, and gender did not significantly affect minor complication rates. Conclusion: RIG tube insertions may serve as a valuable, alternative approach in providing enteral support in patients with neurological disease.

Publisher

Scientific Scholar

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3