Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods

Author:

Tantawy Hazem M.1,Abdelhafez Yasser G.2,Helal Nadia L.3,Saad Ibrahim E.1

Affiliation:

1. Department of Nuclear Medicine Technology, Inaya Medical Colleges, Riyadh, Saudi Arabia,

2. Department of Nuclear Medicine, South Egypt Cancer Institute, Assiut University, Assiut, Egypt,

3. Department of Radiation Safety, Egyptian Nuclear and Radiological Regulatory Authority, Cairo, Egypt,

Abstract

Objectives: Single-photon emission computed tomography/computed tomography (SPECT/CT) hybrid systems have the advantage of performing various scans using the same imaging setting. Absorption and scattering of the gamma rays by the patient’s body significantly affect images obtained from scintigraphy, especially in myocardial perfusion imaging. An important parameter for image quality in SPECT is image contrast which is defined as the difference in density between regions of the image corresponding to different levels of radioactive uptake in the patient. The objective of the study was to evaluate the influence of applying different correction methods on image contrast of myocardial SPECT/CT images. Material and Methods: A total of 114 patients, 43 females and 71 males, patient’s raw data were processed and analyzed using attenuation correction (AC), scatter correction (SC), both attenuation and scatter correction together (ACSC), and no correction (NC). The short axis (coronal) slices resulted from the raw data reconstruction were chosen to perform the processing for hot and cold spheres for contrast values measurement. Statistical analysis was made for the measured contrast values for AC, SC, ACSC, and NC to determine the best image contrast. Results: When applying SC alone, it yields better contrast value (0.834), compared to AC (0.677) and ACSC (0.739). Both ACSC and AC had better image contrast compared to NC (0.592). Conclusion: The intercomparison study between the correction conditions indicates that the counts in SPECT/ CT are highly affected by all correction methods. The image contrast has been significantly improved by using SC, AC, and ACSC when compared with the NC image. Furthermore, SC is superior in the image contrast than the other correction conditions in the reconstruction of SPECT/CT MPI.

Publisher

Scientific Scholar

Subject

Radiology, Nuclear Medicine and imaging

Reference31 articles.

1. Procedure guidelines for radionuclide myocardial perfusion imaging;Anagnostopoulos;Heart,2004

2. Effects of motion, attenuation, and scatter corrections on gated cardiac SPECT reconstruction;Niu;Med Phys,2011

3. Prognostic value of normal stress-only myocardial perfusion imaging: A comparison between conventional and CZT-based SPECT;Yokota;Eur J Nucl Med Mol Imaging,2016

4. Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations;Buvat;J Nucl Med,1995

5. Monte Carlo simulations of a scintillation camera using GATE: Validation and application modelling;Staelens;Phys Med Biol,2003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3