Osteolytic change surrounding biodegradable cement restrictors used in total hip replacements mimicking malignancy

Author:

Ariyaratne Sisith1,Davies Mark1,Evans Scott2,James Steven1,Botchu Rajesh1

Affiliation:

1. Department of Radiology, Royal Orthopedic Hospital, Birmingham, United Kingdom,

2. Department of Orthopedic Oncology, Royal Orthopedic Hospital, Birmingham, United Kingdom,

Abstract

Peri-prosthetic osteolysis is a well-documented complication of total hip arthroplasty. A lesser-known form of peri-prosthetic osteolysis occurs specifically involving biodegradable cement restrictor devices which may be used in total hip replacements (THRs) to contain the cement material within the femoral medullary canal, which would help maintain adequate pressurization within the canal and secure the prosthetic femoral stem. The device is inserted into the femoral medullary canal just distal to the prosthetic stem. Different types of restrictors are used; certain biodegradables forms of restrictors are known to cause progressive osteolysis at the site of insertion, which can present as a gradually enlarging focal lytic lesion on imaging. While this entity as well as its relevance as a risk factor for peri-prosthetic fracture has been discussed in existing literature, the resemblance of this entity to a neoplastic process, particularly given the gradual enlargement over time is not well-documented. Understanding this process and potential pitfall when interpreting imaging, particularly X-rays, in patients who have previously undergone a THR, is important to avoid misdiagnosis of this otherwise benign entity as a neoplastic process and would potentially negate the need for unnecessary investigations.

Publisher

Scientific Scholar

Reference11 articles.

1. Cement restrictor function below the femoral isthmus;Moran;Clin Orthop Relat Res,2007

2. Osteolytic changes around biodegradable cement restrictors in hip surgery;Erschbamer;Acta Orthop,2016

3. Osteolysis in cemented total hip arthroplasty involving the OptiPlug cement restrictor: More than an incident?;Hanssen;Eur J Orthop Surg Traumatol,2013

4. Periprosthetic femoral fracture due to biodegradable cement restrictor;Dhawan;J Arthroplasty,2012

5. Osteolysis associated with optiplug bioabsorbable cement restrictors;Ockendon;J Bone Joint Surgery,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3