Comparison of setup errors between two immobilization techniques for image-guided pelvic radiotherapy: Can an ankle fixator be used as an alternative to a thermoplastic mask for immobilization without compromising treatment?

Author:

Ghosh Arnab Kumar1,Roy Niladri1,Chhatui Bappaditya1,Biswas Jayabrata1,Choudhury Alakananda2,Chakraborty Ipsita1,Saha Udita1,Ravy Aishwarya1,Mazumdar Justice1,Chakrabarty Shinjini1,Barman Rina1

Affiliation:

1. Department of Radiotherapy, Medical College and Hospital, Kolkata, India

2. Department of Radiotherapy, Institute of Post Graduate Medical Education & Research and Seth Sukhlal Karnani Memorial Hospital, Kolkata, India,

Abstract

Objectives Pelvic malignancies have reported large setup variations, requiring good treatment positioning and immobilization. Various immobilization techniques have been reported in literature for pelvic malignancies. In this study, two different immobilization techniques have been compared for translational setup errors during radiation delivery. Material and Methods Kilovoltage cone-beam computed tomography (kV CBCT) scans were taken and 3D-3D matching was done during the first three days of radiation treatment; thereafter once a week, and as per requirement of the particular treatment. Data on translational shifts was tabulated from treatment record. The mean and standard deviation of all individual shifts were calculated using descriptive statistics. The means of the translational shifts of the two arms were compared using Mann–Whitney U test. The population’s systematic and random errors were calculated. Clinical target volume to planning target volume (CTV-PTV) margins were calculated using Van Herk’s method. Results A total of 855 cone-beam computed tomography (CBCT) scans were analyzed. The mean setup errors were not significantly different between two arms in all three translational axes. The CTV-PTV margins in the anteroposterior, superoinferior, and lateral directions are 0.59, 0.94, and 0.78 cm for the TPI arm and 0.84, 0.92, and 0.87 cm for the AFI arm. To have a uniform CTV-PTV margin in all directions, the minimum expansion required is 0.94 cm and 0.92 cm in the TPI and AFI arm, respectively. Conclusion An ankle fixator or similar lower leg immobilization technique can be used as an alternative to thermoplastic mask immobilization without compromising setup accuracy. This has the potential to reduce treatment cost per patient, by excluding the cost of thermoplastic mask.

Publisher

Scientific Scholar

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3