Prediction of effective lens position (ELP) and its changes in different monofocal intraocular lens (IOL’s)

Author:

Pereira Savio1,Ganesh Sri2,Umarani Ramya3,Sute Smith Snehal4

Affiliation:

1. Department of Phaco Refractive, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India,

2. Department of Phaco and Refractive, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India,

3. Department of Phacorefractive, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India,

4. Department of Phaco (Cataract) and Refractive Surgery, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India,

Abstract

Objectives: To evaluate effective lens position (ELP) is more accurately predicted by anterior chamber depth (ACD) alone or by ACD + ½ lens thickness (LT) and to compare the ELP and refractive outcome of different monofocal intraocular lens (IOLs) in patients undergoing phacoemulsification. Materials and Methods: A total of 122 eyes with senile cataract underwent phacoemulsification with three different types of IOL implantation. Biometry data were obtained by IOL master 700 (SS-OCT) and IOL power was calculated using Barrett Universal II formula. Two prediction formulae for ELP were compared, one with ACD + ½ LT and other with ACD alone; furthermore, comparison was done among three types of IOL. Mean prediction error was calculated for both methods and among three IOL groups. Results: In the study, predicted ELP according to ACD + ½ LT was 5.27 ± 0.27 and Mean pre-op ACD was 3.069 ± 0.349 mm, achieved ELP (post-op ACD) was 4.98 ± 0.47 mm and between the two; ACD + ½ LT is closer to achieved ELP. The difference between mean ACD + ½ LT (5.22) and achieved ELP (4.71) was 0.50 in ALCON ACRYSOF IQ (SN60WF) and difference of ACD + ½ LT (5.33) and achieved ELP (5.07) was 0.25 in J and J TECNIS 1 (ZCB00), while the difference of ACD + ½ LT (5.28) and achieved ELP (5.16) was 0.114 in ZEISS CT LUCIA (611P). Residual refraction predicted by IOL master 700 and achieved residual refraction at post-op 1 month was −0.15 ± 0.19 and −0.10 ± 0.30 in ACRYSOF IQ, was −0.11 ± 0.18 and −0.01 ± 0.20 in TECNIS 1 and was −0.10 ± 0.20 and + 0.396 ± 0.22 in ZEISS CT LUCIA, respectively. Conclusion: ELP may be better predicted by formulae ACD + ½ LT than ACD alone with mean differences of 0.29 and 1.92 in two prediction groups, respectively. ALCON ACRYSOF IQ (SN60WF) and J and J TECNIS 1 (ZCB00) group had myopic shifts of 0.10 and 0.11, respectively, while ZEISS CT LUCIA (611P) group had hyperopic shifts of 0.5002 which was statistically significant, as ALCON ACRYSOF IQ (SN60WF) and J and J TECNIS 1 (ZCB00) ELP is positioned more anterior and ZEISS CT LUCIA (611P) relatively posterior.

Publisher

Scientific Scholar

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献