Impedimetric screening for bacteriuria

Author:

Cady P,Dufour S W,Lawless P,Nunke B,Kraeger S J

Abstract

A rapid, automated instrumental procedure for distinguishing urine cultures containing greater than 10(5) organism per ml is described. The method is based upon the measurement of changes in impedance that take place as microorganisms alter the chemical composition of the medium. The time required to detect impedance change is inversely related to the initial concentration of microorganisms in the sample. By defining an impedance-positive culture as one that gives detectable impedance change within 2.6 h, 95.8% of 1,133 urine cultures tested were correctly classified as containing more than or fewer than 10(5) organisms per ml. Selection of a longer detection time decreases false negative results at the cost of increased false positive results. Impedance screening is compared with screening data reported in the literature using adenosine-5'-triphosphate detection, microcalorimetry, electrochemical measurements, and optical microscopy.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference12 articles.

1. Evaluation of an adenosine 5'-triphosphate assay as a screening method to detect significant bacteriuria;Alexander D. N.;J. Clin. Microbiol.,1976

2. Beezer A. E. K. A. Bettelheim R. D. Newell and J. Stevens. 1974. The diagnosis of bacteriuria by flow False negative Positive samples Agreement samples (%) missed (%) 3/68 (4.4) 3/40 (7.5) 63/68 (92.6) 4/299 (1.3) 4/150 (2.7) 251/299 (84.0) 17/348 (4.9) 17/63 (27.0) 311/348 (89.4)

3. Cady P. 1975. Rapid automated bacterial identification by impedance measurement p. 73-99. In C. G. Heden and T. Illeni (ed.) New approaches to the identification of microorganisms. John Wiley & Sons Inc. New York.

4. Chappelle E. W. and G. W. Picciolo. 1971. Bacterial adenosine triphosphate (ATP) as a measure of urinary tract infection. NASA publication TSP1-10051 National Aeronautics and Space Administration Greenbelt Md.

5. Hadley W. K. and G. Senyk. 1975. Early detection of microbial metabolism and growth by measurement of electrical impedance p. 12-21. In D. Schlessinger (ed.) Microbiology-1975. American Society for Microbiology Washington D. C.