Affiliation:
1. Microbiology Department, Montana State University, Bozeman, Montana 59717
Abstract
ABSTRACT
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen
Escherichia coli
O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown
E. coli
O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and
r
2
= 0.95 (
n
= 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and
r
2
= 0.98 (
n
= 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of
E. coli
O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference35 articles.
1. Prevalence and clinical manifestations of Shiga toxin-producing Escherichia coli infections in Austrian children.;Allerberger F.;Eur. J. Clin. Microbiol. Infect. Dis.,1996
2. Escherichia coli O157:H7 infections associated with eating a nationally distributed commercial brand of frozen ground beef patties and burger—Colorado, 1997.;Anonymous;Morbid. Mortal. Weekly Rep.,1997
3. Outbreaks of Escherichia coli O157:H7 infection associated with eating alfalfa sprouts—Michigan and Virginia, June–July 1997.;Anonymous;JAMA,1997
4. Atlas
R. M.
Alphabetical listing of media
Handbook of microbiological media.
Parks
L. C.
1993
1015
CRC Press Inc.
Boca Raton Fla
5. Bangs Laboratories
Adsorption protocols. Technical note 13a
1996
7
Bangs Laboratories Inc.
Carmel Ind
Cited by
112 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献