Comparative evaluation of the oxoid signal and Roche Septi-Chek blood culture systems

Author:

Murray P R1,Niles A C1,Heeren R L1,Curren M M1,James L E1,Hoppe-Bauer J E1

Affiliation:

1. Barnes Hospital Clinical Microbiology Laboratory, St. Louis, Missouri 63110.

Abstract

The Oxoid Signal blood culture system (Oxoid USA, Inc., Columbia, Md.) was compared with the Roche Septi-Chek system (Roche Diagnostics, Div. Hoffmann-La Roche Inc., Nutley, N.J.), with the latter consisting of a tryptic soy broth (R-TSB) bottle with an attached agar slide unit and a Columbia broth bottle. A total of 5,034 cultures with equal volumes of blood in each bottle were processed. Overall, more organisms were recovered in the R-TSB bottle than in the Signal bottle, with significantly more aerobic organisms (Pseudomonas spp., Acinetobacter spp., and yeasts) recovered in the R-TSB bottles and anaerobes and viridans group streptococci recovered in Signal bottles. Approximately equivalent numbers of organisms were recovered in the Signal and Columbia broth bottles. The times of detection were essentially identical with the three blood culture broth systems. During the study, 30.6% of the Signal bottles had a positive indicator of growth, of which 1,103 (71.7%) were false-positive cultures. Additionally, nonviable organisms resembling streptococci were observed in 13.7% of the Signal bottles that were Gram stained and in unioculated blood culture bottles. With appropriate modifications of the preparation of the media, the latter problem can be eliminated.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference15 articles.

1. Colton T. 1974. Statistics in medicine. Little Brown & Co. Boston.

2. Early detection of bacterial growth, with carbon-14-labeled glucose;DeLand F. H.;Radiology,1969

3. Improvement of positive blood culture detection by agitation;Hawkins B. L.;Diagn. Microbiol. Infect. Dis.,1986

4. Microbiological and clinical evaluation of the Isolator Iysis-centrifugation blood culture tube;Henry N. K.;J. Clin. Microbiol.,1983

5. Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system;Jungkind D.;J. Clin. Microbiol.,1986

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Conventional Blood Culture Methods;The Dark Art of Blood Cultures;2017-08-24

2. Biographical Feature: Patrick R. Murray, Ph.D;Journal of Clinical Microbiology;2016-08

3. Commercial Blood Culture Systems and Methods;Manual of Commercial Methods in Clinical Microbiology;2016-04-01

4. Sepsis Pathogen Identification;Journal of Laboratory Automation;2015-10

5. Laboratory Detection of Bacteremia and Fungemia;Manual of Clinical Microbiology;2015-05-26

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3