Evaluation of Four Commercially Available Epstein-Barr Virus Enzyme Immunoassays with an Immunofluorescence Assay as the Reference Method

Author:

Gärtner Barbara C.1,Hess Ralf D.2,Bandt Dirk3,Kruse Alexander3,Rethwilm Axel3,Roemer Klaus1,Mueller-Lantzsch Nikolaus1

Affiliation:

1. Department of Virology, EBV Reference Center, University Homburg/Saar, Homburg/Saar

2. HISS Diagnostics GmbH, Freiburg

3. Institute of Virology, University of Dresden, Dresden, Germany

Abstract

ABSTRACT Four commercially available enzyme immunoassays (EIAs) (Novitec, Biotest, Virotech, and DiaSorin) were evaluated, with an indirect immunofluorescence assay as the reference method, for Epstein-Barr virus (EBV) VCA (viral capsid antigen) immunoglobulin G (IgG), VCA IgM, or EBNA (EBV nuclear antigen) IgG at three different locations (Homburg, Stuttgart, and Dresden). Serum samples from 66 immunocompetent patients with infectious mononucleosis, 73 patients without prior EBV infection, and 96 patients with past EBV infections and 29 serum samples with possible cross-reactions to other herpesviruses were included. In addition, 25 samples from an extensively pretested panel that is commercially available (Boston Biomedica) were tested. Each sample was tested at only one location. The four EIAs varied considerably in performance. When analyzing for EBV diagnosis, the Novitec assay performed the best, with 4.9% discrepant diagnoses, followed by the Biotest, Virotech, and DiaSorin assays, with 6.8, 11.7, and 14.0% discrepant diagnoses, respectively. On the basis of single-parameter analysis, the Novitec assay also showed the lowest number of discrepant results, with 3.5%, compared with the Virotech, Biotest, and DiaSorin assays, which produced 5.4, 6.4, and 8.6% discrepant results, respectively. VCA assays using affinity-purified native antigens performed better than assays with recombinant or synthetic antigens. The synthetic EBNA-1s showed the lowest concordance with the reference compared to recombinant p72. Commercially available EBV EIAs differed considerably in performance; however, some proved to be reliable and convenient alternatives to the indirect immunofluorescence assay for routine diagnostics. Native antigens, rather than synthetic peptides, are favored for EBV serology testing.

Publisher

American Society for Microbiology

Subject

Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3