Collaborative study for the evaluation of enzyme-linked immunosorbent assays used to measure human antibodies to Bordetella pertussis antigens

Author:

Lynn F1,Reed G F1,Meade B D1

Affiliation:

1. Laboratory of Pertussis, Food and Drug Administration, Rockville, Maryland 20852, USA. lynn@a1.cber.fda.gov.

Abstract

Acellular pertussis vaccines are being evaluated in multiple clinical studies, and human immunogenicity data will likely be pivotal in the appraisal of vaccine responses between populations and the responses to different vaccine combinations. Antibody response to pertussis antigens is also used in the diagnosis of pertussis. An international study was designed to assess the comparability of data generated in different laboratories by enzyme-linked immunosorbent assays (ELISAs). Thirty-three participating laboratories were asked to quantitate specific antibody to pertussis toxin (PT), filamentous hemagglutinin (FHA), pertactin (PRN), or fimbrial proteins (FIM) in 21 samples. Samples were to be assayed in triplicate in five independent assays by each ELISA routinely performed in the laboratory to assess intra-assay, interassay, and population variability. The mean sample values were used to compare quantitative results among the laboratories. Thirteen of the 32 laboratories which submitted evaluable data for an assay to measure antibodies to PT, 12 of 30 laboratories with assays for FHA, 10 of 17 laboratories with assays for PRN, and 6 of 13 laboratories with assays for FIM maintained a coefficient of variation below 20% for 75% of the samples tested. Assays that measure antibodies to FIM appear to be less precise than the other assays. Precision varied among laboratories that used similar methods. The relative values of intra- and interassay variabilities were not consistent for a given assay within a laboratory, indicating that the sources of these variability components may be unrelated. Precision and agreement appeared less reliable for samples with low antibody levels. Ranking and regression analyses suggest that some laboratories generated comparable quantitative results, although direct comparison or combination of results from different laboratories remains difficult to support. Calibration to the U.S. Reference Pertussis Antisera appears to have been successful at standardizing the results in some laboratories. Statistical analyses are affected by assay precision and are not necessarily reliable sole predictors of biologically relevant differences in quantitative results. If results from different laboratories must be compared, appropriate studies of precision and quantitative agreement should be conducted to support the specific comparisons.

Publisher

American Society for Microbiology

Subject

Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy

Reference22 articles.

1. Ad Hoc Group for the Study of Pertussis Vaccines. 1988. Placebo-controlled trial of two acellular vaccines in Sweden-protective efficacy and adverse effects. Lancet i:955-960.

2. Bishop Y. M. M. S. E. Fienberg and P. W. Holland. 1975. Discrete multivariate analysis. MIT Press Cambridge Mass.

3. Multicenter comparison of levels of antibody to the Neisseria meningitidis group A capsular polysaccharide measured by using an enzyme-linked immunosorbent assay;Carlone G. M.;J. Clin. Microbiol.,1992

4. Chambers J. M. and W. S. Cleveland. 1983. Graphical methods for data analysis. Wadsworth International Group Belmont Calif. and Duxbury Press Boston.

5. Conover W. J. 1971. Practical nonparametric statistics. John Wiley & Sons Inc. New York.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3