Optimized Pathogen Detection with 30- Compared to 20-Milliliter Blood Culture Draws

Author:

Patel Robin12,Vetter Emily A.1,Harmsen W. Scott3,Schleck Cathy D.3,Fadel Hind J.2,Cockerill Franklin R.12

Affiliation:

1. Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology

2. Division of Infectious Diseases, Department of Medicine

3. Division of Biomedical Statistics and Informatics, Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota 55905

Abstract

ABSTRACT Using data from 23,313 patients, we assessed whether two blood culture sets of three bottles per set would detect more pathogens than two sets of two bottles per set and achieve similar sensitivity to collecting three sets of two bottles per set. We also compared the yield of aerobic and anaerobic bottles. Thirty milliliters of blood was distributed to one anaerobic and two aerobic bottles. Among 26,855 collections of ≥60 ml within 30 min, 1,379 (5.1%) were positive for a pathogen not requiring detection in more than one set to be considered a pathogen, with 72 additional distinct pathogens detected using two 30-ml compared to two 20-ml sets of one aerobic and one anaerobic bottle (increased yield, 7.9%; 95% confidence interval [CI], 6.2 to 9.8%). For conditional pathogens requiring detection in at least two positive blood cultures for classification as pathogens (i.e., otherwise classified as contaminants), there were 162 positive detections with two 30-ml sets, of which 16 would not have been detected by two 20-ml sets (increased yield, 11.0% [95% CI, 6.4 to 17.2%]). Among 134 subjects who had three sets of 30 ml each within a 30-min interval, there was complete concordance between 60 ml of blood drawn in the first two sets of 30 ml and three 20-ml sets ( P = 1.0). One aerobic bottle plus one anaerobic bottle yielded more pathogens than two aerobic bottles for organisms requiring a single ( P < 0.001) and two ( P = 0.04) positive sets to be defined as pathogens. In conclusion, we showed that collection of two aerobic and one anaerobic blood culture bottles per set results in improved yield compared to two bottles per set. We also confirmed that an anaerobic bottle should be included in blood culture sets.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3