Water samples from clay storage jugs ("zeers") located in homes and at public watering stands ("sebeels") at streets, mosques, and schools were examined. Coliforms, fecal coliforms, and fecal streptococci were detected in 100, 69, 88, and 91.56% of the samples, respectively. The general microbiology of the water and some factors affecting microbial load were studied. The predominant bacterial genera of sebeel water were found to be Staphylococcus. Aerococcus, Micrococcus, Streptococcus, Bacillus, Listeria, Lactobacillus, and Arthrobacter. A simple modification of zeer construction was suggested to help improve sanitation.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference9 articles.
1. American Public Headth Association. 1971. Standard methods for the examination of water and wastewater 13th ed. American Public Health Association Inc. Washington D.C.
2. Coliform bacilli in water;Bardsley D. A.;J. Hyg.,1934
3. A comparison of two methods of assessing the number of different types of coliform organisms in water;Bardsley D. A.;J. Hyg.,1938
4. An examination of the modified Eijkman method applied to pure coliform cultures obtained from water in Singapore;Bouzot G. E.;J. Hyg.,1941
5. Buchanan R. E. and N. E. Gibbons (ed.). 1974. Bergey's manual of determinative bacteriology 8th ed. The Williams and Wilkins Co. Baltimore.