Recovery Efficiency and Limit of Detection of Aerosolized Bacillus anthracis Sterne from Environmental Surface Samples

Author:

Estill Cheryl Fairfield1,Baron Paul A.1,Beard Jeremy K.2,Hein Misty J.1,Larsen Lloyd D.2,Rose Laura3,Schaefer Frank W.4,Noble-Wang Judith3,Hodges Lisa3,Lindquist H. D. Alan4,Deye Gregory J.1,Arduino Matthew J.3

Affiliation:

1. Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 4676 Columbia Parkway, Cincinnati, Ohio 45226

2. Dugway Proving Ground, P.O. Box 217, Dugway, Utah 84022

3. Centers for Disease Control and Prevention, Center for Infectious Diseases, 1600 Clifton Road, N.E., Atlanta, Georgia 30333

4. U.S. Environmental Protection Agency, National Homeland Security Research Center, 26 W. M. L. King Drive, Cincinnati, Ohio 45268

Abstract

ABSTRACT After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm 2 ). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm 2 ) or wipe or vacuum (929 cm 2 ) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm 2 ) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm 2 for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm 2 for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans.

Publisher

American Society for Microbiology

Subject

Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3