Affiliation:
1. Medical Laboratory of Taizhou Fourth People’s Hospital, Taizhou, China
2. Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
Abstract
ABSTRACT
Staphylococcus aureus
(
S. aureus
) is a leading cause of bacteremia and blood stream infections. Methicillin-resistant
S. aureus
(MRSA) that first appeared in 1961 often caused hospital-acquired infections (HAIs) and community-acquired infections (CAIs) and was associated with high mortality rate. Accurate and rapid point-of-care testing (POCT) of MRSA is crucial for clinical management and treatment of MRSA infections, as well as the prevention and control of HAIs and CAIs. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of methicillin-susceptible
S. aureus
and MRSA. The dual HiFi-LAMP assay can detect 30 copies/reaction of
nuc
and
mecA
genes with detection limits of 147 and 158 copies per 25 µL reaction, respectively. A retrospective clinical evaluation with 107 clinical
S. aureus
isolates showed both sensitivity and specificity of 100%. A prospective clinical evaluation with 35 clinical samples revealed a specificity of 100% and a sensitivity of 92.3%. The dual HiFi-LAMP assay can detect almost all
S. aureus
samples (141/142; 99.3%) within 20 min, implying that the entire HiFi-LAMP assay (including sample process) can be completed within 40 min, extremely significantly shorter than 3–5 days by the traditional clinical microbial culture and antibiotic susceptibility testing. The novel extraction-free dual HiFi-LAMP assay can be used as a robust POCT tool to promote precise diagnosis and treatment of MRSA infections in hospitals and to facilitate surveillance of MRSA at hospital and community settings.
IMPORTANCE
Methicillin-resistant
Staphylococcus aureus
(MRSA) was associated with high mortality rate and listed as a “priority pathogen” by the World Health Organization. Accurate and rapid point-of-care testing (POCT) of MRSA is critically required for clinical management and treatment of MRSA infections. Some previous LAMP-based POCT assays for MRSA might be questionable due to their low specificity and the lack of appropriate evaluation directly using clinical samples. Furthermore, they are relatively tedious and time-consuming because they require DNA extraction and lack multiplex detection capacity. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of MRSA and methicillin-susceptible
S. aureus
. The assay has high specificity and sensitivity and can be completed within 40 min. Clinical evaluation with real clinical samples and clinical isolates showed excellent performance with 100% specificity and 92.3%–100% sensitivity. The novel extraction-free assay may be a robust POCT tool to promote precise diagnosis of MRSA infections and facilitate surveillance of MRSA at hospital and community settings.
Funder
STCSM | Science and Technology Innovation Plan of Shanghai Science and Technology Commission
Science and Technology Support Foundation of Taizhou city
Publisher
American Society for Microbiology