Use of Pooled Urine Samples and Automated DNA Isolation To Achieve Improved Sensitivity and Cost-Effectiveness of Large-Scale Testing for Chlamydia trachomatis in Pregnant Women

Author:

Rours G. I. J. G.1,Verkooyen R. P.2,Willemse H. F. M.2,van der Zwaan E. A. E.2,van Belkum A.2,de Groot R.1,Verbrugh H. A.2,Ossewaarde J. M.2

Affiliation:

1. Department of Paediatrics, Erasmus MC—Sophia Children's Hospital, Rotterdam, The Netherlands

2. Department of Medical Microbiology and Infectious Diseases, Erasmus MC, Rotterdam, The Netherlands

Abstract

ABSTRACT The success of large-scale screening for Chlamydia trachomatis depends on the availability of noninvasive samples, low costs, and high-quality testing. To evaluate C. trachomatis testing with pregnant women, first-void urine specimens from 750 consecutive asymptomatic pregnant women from the Rotterdam area (The Netherlands) were collected. Initially, we investigated the performance of three different DNA isolation methods with 350 of these urines and 70 pools of 5 of the same subset of urine samples. The routinely used COBAS AMPLICOR test was compared to the COBAS AMPLICOR test with prior DNA isolation by use of the MagNA Pure large-volume kit and the MagNA Pure bacterial DNA isolation kit. The latter combination provided the best DNA test for pooled urines, with a sensitivity twice that of the other methods. Next, using all 750 urines, the COBAS AMPLICOR performance for individual testing was compared to pooled testing with the standard COBAS AMPLICOR procedure and subsequently to pooled testing with COBAS AMPLICOR in combination with the MagNA Pure bacterial DNA isolation kit. The sensitivity of COBAS AMPLICOR was 65% on individual and 42% on pooled urines but improved to 92% on pooled urines with the MagNA Pure bacterial DNA isolation kit, making this combination the best screening method. The C. trachomatis prevalence in this population appeared to be 6.4%. Additionally, the cost of the combined MagNA Pure bacterial DNA isolation kit and COBAS AMPLICOR method on pooled urines was only 56% of the cost of the standard COBAS AMPLICOR test applied to individual urines. Costs per positive case detected in the combined method were 39% of standard costs.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3