Affiliation:
1. Division of Infectious Diseases, Wilford Hall U.S. Air Force Medical Center, Lackland Air Force Base, Texas 78236.
Abstract
Four commercially available rapid agglutination tests for the identification of Staphylococcus aureus were compared with the tube coagulase test for the identification of 300 methicillin-resistant isolates of staphylococci. Isolates tested included 207 methicillin-resistant S. aureus and 93 coagulase-negative staphylococci, collected from five medical centers. Strain variability was documented by phage typing and antimicrobial susceptibility patterns. Results of rapid identification tests ranged between 82 and 86% sensitivity, significantly poorer than the 98% sensitivity which the tube coagulase test provided.
Publisher
American Society for Microbiology
Cited by
27 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献