Recent analytical methods for cephalosporins in biological fluids

Author:

Toothaker R D,Wright D S,Pachla L A

Abstract

Since 1980, RP chromatography has been the principal analytical technique used for cephalosporins. This technology offers selectivity, accuracy, and ease of use. Most of the methods rely on protein precipitation and, to a lesser extent, solid-phase isolation or extraction procedures. The proper selection of a method depends on the analytical constraints imposed by the overall objective of the study. For example, pharmacokinetic datum interpretation mandates that the method be validated and provide specific and accurate results. LC is the preferred technique, since it not only meets these specifications but may also distinguish between the drug and metabolites. Those chromatographic methods which quantify several different cephalosporins are not desirable for pharmacokinetic datum interpretation, since accuracy and precision are usually compromised in order that many different drugs may be quantified in a single analysis. The proper selection of sample preparation method is dependent on the presence of potential interferences and the acceptable lower limit of quantitation. Protein precipitation methods offer ease of sample preparation but may suffer from nonselectivity. Solid-phase isolation and extraction procedures may increase selectivity and improve the limit of quantitation. Although LC provides specific and accurate results, clinical laboratories may prefer to use the less specific methods for therapeutic drug monitoring. In this case, microbiological, enzymatic, and fluorimetric methods offer improved sample throughput but less specificity. However, these methods should not be used for drugs that may have a low margin of safety or if the patient is on multiple-antibiotic therapy. Future methods may involve incorporating solid-phase isolation columns to enhance the specificity of chromatographic, microbiological, enzymatic, and fluorescence methods. Advancements in microbore column technology may allow improvements in the selectivity and sensitivity of LC methods. Many investigators prefer to use simple protein precipitation procedures for sample preparation because of sample throughput constraints. However, advances in robotic sample preparation may allow the more cumbersome solid-phase isolation or extraction techniques to be used to improved sample throughput and specificity.

Publisher

American Society for Microbiology

Subject

Infectious Diseases,Pharmacology (medical),Pharmacology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3