Comparisons of Community-Associated Methicillin-Resistant Staphylococcus aureus (MRSA) and Hospital-Associated MSRA Infections in Sacramento, California

Author:

Huang Hsin1,Flynn Neil M.1,King Jeff H.1,Monchaud Caroline1,Morita Margaret1,Cohen Stuart H.1

Affiliation:

1. Department of Infectious Disease, Department of Internal Medicine, University of California, Davis, Medical Center, Sacramento, California 95817

Abstract

ABSTRACT Methicillin-resistant Staphylococcus aureus (MRSA) has long been a common pathogen in healthcare facilities, but in the past decade, it has emerged as a problematic pathogen in the community setting as well. A retrospective case series study of patients from whom MRSA was isolated from December 1, 2003, through May 31, 2004, was conducted at the University of California, Davis, Medical Center. Patient data were collected from electronic medical records and traditional chart reviews to determine whether MRSA acquisition was likely to have been in the community or in the hospital. Antimicrobial susceptibility testing and pulsed-field gel electrophoresis (PFGE) were performed for all confirmed isolates. Skin and soft tissue were the most common infection sites for all MRSA patients. Among the 283 MRSA infections, 127 (44.9%) were defined as community-associated (CA)-MRSA. Ninety-six percent of the CA-MRSA isolates were susceptible to clindamycin. Double-disk diffusion tests were performed to examine inducible clindamycin resistance by erythromycin induction on both CA and hospital-associated (HA) clindamycin-susceptible and erythromycin-resistant isolates. Ten percent (17 of 183) were positive. Most CA-MRSA isolates were identified by PFGE as a unique strain, genotype USA300, which was not genetically related to the predominant genotype, USA100, in the HA-MRSA isolates. Injecting drug users accounted for 49% of CA-MRSA infections but only 19% of the HA-MRSA infections (odds ratio, 4.2; 95% confidence interval, 2.4 to 7.4). Our study shows that a single clone of CA-MRSA accounts for the majority of infections. This strain originated in the community and is not related to MRSA strains from healthcare settings. Injecting drug users could be a major reservoir for CA-MRSA transmission.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 132 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3