Use of Swabs without Transport Media for the Gen-Probe Group A Strep Direct Test

Author:

Bourbeau Paul P.1,Heiter Barbara J.1

Affiliation:

1. Division of Laboratory Medicine, Geisinger Medical Center, Danville Pennsylvania 17822-0131

Abstract

ABSTRACT For several years we used rayon or Dacron swabs with liquid transport media for collection and transport of throat swab specimens for testing with the Gen-Probe Group A Strep Direct Test (GASDT). A report of favorable results with a Dacron swab without any transport media for GASDT by another laboratory prompted us to compare detection of group A streptococci (GAS) with and without transport media (referred to as “wet” and “dry” swabs, respectively). Phase one of this study used swabs seeded with GAS. Initially, six recent clinical isolates of GAS were inoculated onto wet and dry swabs and stored at room temperature (RT). After 1, 2, and 3 days of storage, colony counting and GASDT were performed with the swabs. The results, expressed as the mean percentage of the results at zero time, were as follows: for GASDT with wet swabs at 1, 2, and 3 days, 62, 51, and 56%, respectively; for GASDT with dry swabs at 1, 2, and 3 days, 105, 80, and 85%, respectively; for colony counts with wet swabs at 1, 2, and 3 days, 52, 26, and 13%, respectively; for colony counts with dry swabs at 1, 2, and 3 days, 10, 0, and 0%, respectively. An additional six strains of GAS were tested in a similar manner, except that extracts of pharyngeal flora (PF) were added to the inocula. The results obtained with extracts of PF were comparable to those obtained with GAS alone. We also compared the performance of GASDT with wet and dry swabs stored at RT and 4°C. Ten strains of GAS were inoculated onto wet and dry swabs, and GASDT was performed each day for 9 days. The GASDT results for swabs on day 9, expressed as the mean percentage of the results obtained at zero time, were as follows: dry swab and 4°C, 59%; wet swab and 4°C, 31%; dry swab and RT, 33%; and wet swab and RT, 19%. In phase two of this study we conducted a clinical evaluation to determine whether the differences observed with seeded specimens would also be evident with patient specimens. We used a single dry Dacron swab paired with a single rayon Bacti-Swab with liquid Stuart transport medium for the clinical evaluation. Specimens were collected from 1,005 outpatients, plated onto a Strep Selective Agar plate, and then tested within 30 min by GASDT. If culture of GAS from the same swab is used to define a true-positive test result, the sensitivities and specificities were as follows: GASDT with wet swabs, 86.2 and 98.5%, respectively; GASDT with dry swabs, 90.7 and 98.1%, respectively. However, the use of culture as the “gold standard” may understate the actual performance characteristics of GASDT, particularly for the dry swabs. In conclusion, for GASDT the use of swabs without transport media may be preferable to the use of swabs with transport media.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3