Affiliation:
1. Department of Pathology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226
2. Department of Microbiology, Milwaukee County General Hospital, Milwaukee, Wisconsin 53226
Abstract
This paper describes the comparison of the Sterifil lysis-filtration (SLF) blood culture procedure with a standard Trypticase soy broth (TSB) technique. The lysing solutions employed in the SLF system, Triton X-100 (alkyl phenoxy polyethoxy ethanol) and sodium carbonate, were deleterious to most bacteria commonly encountered in bacteremia except staphylococci and enterococci.
Candida
was not adversely affected. There was a positive correlation between the tolerance of the microbial isolants to the lysing solutions and their recovery by the SLF technique. A total of 3,554 cultures were run in parallel and 398 isolants were obtained. Of 201 gram-positive isolants, 135 were recovered by both techniques, 43 were detected by the TSB technique only, and 23 were recovered only with the SLF method. In sharp contrast, of 168 gram-negative isolants, 28 were recovered in common, 130 were isolated only by TSB, and 10 were recovered only with the SLF method. The SLF method detected all cases of candidemia detected by the TSB method plus an additional 12 for a total of 29 cases. The SLF method, as currently described, is generally too toxic to bacteria for routine use in a clinical laboratory.
Publisher
American Society for Microbiology
Subject
General Pharmacology, Toxicology and Pharmaceutics,General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献