Limulus amoebocyte lysate and direct sampling methods for surveillance of operating nebulizers

Author:

Reinhardt D J,Nabors W,Kennedy C,Malecka-Griggs B

Abstract

The Limulus amoebocyte lysate test for detection of endotoxin (Pyrogent; Mallinckrodt Chemical Co.) and the Easicult method (Orion Diagnostica) for detection of bacteria were compared with direct dilution sampling, a standardized technique for respiratory therapy surveillance previously developed in our laboratory. Tests of 206 reservoirs of nebulizers were done in three hospitals in Georgia. Forty-five percent of all reservoirs sampled were contaminated. Gram-negative, nonfermentative bacilli were the predominant contaminants. The results of the Limulus test and the Easicult system were in agreement with those of the direct dilution sampling tests approximately 84 and 90% of the time, respectively. Direct dilution of water samples onto blood agar plates was the most sensitive, reliable, and informative method for detecting viable bacteria. The Easicult and Limulus systems were sensitive enough to detect greater than or equal to 10(3) colony-forming units per ml. Positive Limulus tests and negative culture tests, reflecting detection of endotoxin but not of viable gram-negative bacteria, occurred in 20 of 206 (9.7%) instances. Positive cultures and negative Limulus tests were noted in 13 of 206 (6.8%) samplings. The Limulus test is a valuable procedure, for it can detect moderate-to-heavy microbial contamination within 1 h of testing and affords the opportunity to remove contaminated equipment from patients within minutes of a positive test result. These results demonstrate the potential value of the Easicult and Limulus tests for selective surveillance of operating nebulizers.

Publisher

American Society for Microbiology

Subject

Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology

Reference28 articles.

1. The metabolism of coliform bacilli in distilled water;Bigger J. W.;J. Pathol. Biol.,1943

2. Factors affecting comparative resistance of naturally occurring and subcultured Pseudomonas aeruginosa to disinfectants;Carson L. A.;Appl. Microbiol.,1972

3. Morphological, biochemical, and growth characteristics of Pseudomonas cepacia from distilled water;Carson L. A.;Appl. Microbiol.,1973

4. Environmental microbiologic sampling in the hospital;Committee on Medical Contamination of Surfaces, Laboratory Section, American Public Health Association.;Health Lab. Sci.,1975

5. Nebulization equipment-a potential source of infection in gram negative pneumonias;Edmondson E. B.;Am. J. Dis. Child.,1966

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3