Performance evaluation of the high-throughput quantitative Alinity m BK virus assay

Author:

Hirschhorn Julie W.1,Sasaki Mark M.2,Kegl April1,Akter Tanjina1,Dickerson Tanisha1,Narlieva Momka3,Nhan Nhi3,Liu Tianxi3,Jim Patricia4,Young Stephen4,Orner Erika3ORCID,Thwe Phyu3,Lucic Danijela2,Goldstein D. Yitzchak3ORCID

Affiliation:

1. Department of Pathology and Laboratory Medicine, Medical University of South Carolina, Charleston, South Carolina, USA

2. Molecular Diagnostics of Abbott, Des Plaines, Illinois, USA

3. Department of Pathology, Montefiore Medical Center, Bronx, New York, USA

4. TriCore Reference Laboratories, Albuquerque, New Mexico, USA

Abstract

ABSTRACT BK virus (BKV) infection or reactivation in immunocompromised individuals can lead to adverse health consequences including BKV-associated nephropathy (BKVAN) in kidney transplant patients and BKV-associated hemorrhagic cystitis (BKV-HC) in allogeneic hematopoietic stem cell transplant recipients. Monitoring BKV viral load plays an important role in post-transplant patient care. This study evaluates the performance of the Alinity m BKV Investigational Use Only (IUO) assay. The linearity of the Alinity m BKV IUO assay had a correlation coefficient of 1.000 and precision of SD ≤ 0.25 Log IU/mL for all panel members tested (2.0–7.3 Log IU/mL). Detection rate at 50 IU/mL was 100%. Clinical plasma specimens tested comparing Alinity m BKV IUO to ELITech MGB Alert BKV lab-developed test (LDT) on the Abbott m 2000 platform using specimen extraction protocols for DNA or total nucleic acid (TNA) resulted in coefficient of correlation of 0.900 and 0.963, respectively, and mean bias of 0.03 and −0.54 Log IU/mL, respectively. Alinity m BKV IUO compared with Altona RealStar BKV and Roche cobas BKV assays demonstrated coefficient of correlation of 0.941 and 0.980, respectively, and mean bias of −0.47 and −0.31 Log IU/mL, respectively. Urine specimens tested on Alintiy m BKV IUO and ELITech BKV LDT using TNA specimen extraction had a coefficient of correlation of 0.917 and mean bias of 0.29 Log IU/mL. The Alinity m BKV IUO assay was performed with high precision across the dynamic range and correlated well with other available BKV assays. IMPORTANCE BK virus (BKV) in transplant patients can lead to adverse health consequences. Viral load monitoring is important in post-transplant patient care. This study evaluates the Alinity m BKV assay with currently available assays.

Publisher

American Society for Microbiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3