Comparative Evaluation of the VITEK 2, Disk Diffusion, Etest, Broth Microdilution, and Agar Dilution Susceptibility Testing Methods for Colistin in Clinical Isolates, Including Heteroresistant Enterobacter cloacae and Acinetobacter baumannii Strains

Author:

Lo-Ten-Foe Jerome R.1,de Smet Anne Marie G. A.2,Diederen Bram M. W.1,Kluytmans Jan A. J. W.13,van Keulen Peter H. J.1

Affiliation:

1. Laboratory for Microbiology and Infection Control, Amphia Hospital, Breda, The Netherlands

2. Perioperative and Emergency Care, Utrecht Medical Center, Utrecht, The Netherlands

3. Medical Microbiology and Infection Control, VUmc Medical University, Amsterdam, The Netherlands

Abstract

ABSTRACT Increasing antibiotic resistance in gram-negative bacteria has recently renewed interest in colistin as a therapeutic option. The increasing use of colistin necessitates the availability of rapid and reliable methods for colistin susceptibility testing. We compared seven methods of colistin susceptibility testing (disk diffusion, agar dilution on Mueller-Hinton [MH] and Isosensitest agar, Etest on MH and Isosensitest agar, broth microdilution, and VITEK 2) on 102 clinical isolates collected from patient materials during a selective digestive decontamination or selective oral decontamination trial in an intensive-care unit. Disk diffusion is an unreliable method to measure susceptibility to colistin. High error rates and low levels of reproducibility were observed in the disk diffusion test. The colistin Etest, agar dilution, and the VITEK 2 showed a high level of agreement with the broth microdilution reference method. Heteroresistance for colistin was observed in six Enterobacter cloacae isolates and in one Acinetobacter baumannii isolate. This is the first report of heteroresistance to colistin in E. cloacae isolates. Resistance to colistin in these isolates seemed to be induced upon exposure to colistin rather than being caused by stable mutations. Heteroresistant isolates could be detected in the broth microdilution, agar dilution, Etest, or disk diffusion test. The VITEK 2 displayed low sensitivity in the detection of heteroresistant subpopulations of E. cloacae . The VITEK 2 colistin susceptibility test can therefore be considered to be a reliable tool to determine susceptibility to colistin in isolates of genera that are known not to exhibit resistant subpopulations. In isolates of genera known to (occasionally) exhibit heteroresistance, an alternative susceptibility testing method capable of detecting heteroresistance should be used.

Publisher

American Society for Microbiology

Subject

Infectious Diseases,Pharmacology (medical),Pharmacology

Reference22 articles.

1. Andrews, J., R. Walker, and A. King. 2002. Evaluation of media available for testing the susceptibility of Pseudomonas aeruginosa by BSAC methodology. J. Antimicrob. Chemother.50:479-486.

2. Andrews, J. M. 2001. The development of the BSAC standardized method of disc diffusion testing. J. Antimicrob. Chemother.48(Suppl. 1):29-42.

3. Reliability of the E-Test Method for Detection of Colistin Resistance in Clinical Isolates of Acinetobacter baumannii

4. Fifteenth information supplement (M100-S15). 2005

5. Seventeenth information supplement (M100-S17). 2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司