Controlled evaluation of BacT/alert standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia

Author:

Wilson M L1,Weinstein M P1,Mirrett S1,Reimer L G1,Feldman R J1,Chuard C R1,Reller L B1

Affiliation:

1. Department of Pathology and Laboratory Service, Denver Health & Hospitals, Colorado 80204, USA.

Abstract

FAN medium was formulated to improve microbial recovery, particularly for fastidious microorganisms and for microorganisms causing sepsis in patients receiving antimicrobial therapy. In a controlled clinical evaluation performed at four university-affiliated hospitals, FAN anaerobic bottles were compared with standard anaerobic bottles for yield, speed of detection of microbial growth, and detection of septic episodes. A total of 10,431 blood culture sets were received; both anaerobic bottles of 7,694 blood culture sets were adequately filled with blood. Altogether, 925 isolates were recovered: 557 that were the cause of sepsis, 99 that were indeterminate as the cause of sepsis, and 269 contaminants. More Staphylococcus aureus (P < 0.001), coagulase-negative staphylococci (P < 0.001), Escherichia coli (P < 0.02), and all microorganisms combined (P < 0.005) were recovered from FAN bottles; more nonfermentative gram-negative bacilli (P < 0.05), Torulopsis glabrata (P < 0.001), and other yeasts (P < 0.01) were recovered from standard bottles. Growth of S. aureus (P < 0.001), coagulase-negative staphylococci (P < 0.001), Enterococcus faecalis (P < 0.025), streptococci other than Streptococcus pneumoniae (P < 0.01), and all microorganisms combined (P < 0.001) was detected earlier in standard bottles; growth of more isolates of E. coli (P < 0.05) and anaerobic bacteria (P < 0.01) was detected earlier in FAN bottles. The mean times to detection were 14.2 and 16.1 h for standard and FAN bottles, respectively. More septic episodes caused by S. aureus (P < 0.001), coagulase-negative staphylococci (P < 0.005), members of the family Enterobacteriaceae (P < 0.02), and all microorganisms combined (P < 0.02) were detected in FAN bottles; more septic episodes caused by nonfermentative gram-negative bacilli (P < 0.025) and yeasts (P < 0.005) were detected in standard bottles. In summary, more isolates (except for strict aerobes) were recovered from FAN bottles than from standard anaerobic bottles. Similarly, significant more septic episodes (except for those caused by strict aerobes) were detected with FAN bottles than with standard anaerobic bottles. With the exception of E. coli and anaerobic bacteria, growth of more isolates was detected earlier in standard anaerobic bottles.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3