Rapid, Field-Adapted Indirect Enzyme-Linked Immunosorbent Assay for Detection of Antibodies in Bovine Whole Blood and Serum to Brucella abortus

Author:

Gall D.1,Nielsen K.1,Yu W.1,Smith P.1

Affiliation:

1. Canadian Food Inspection Agency, Ottawa Laboratory Fallowfield, Ottawa, Ontario, Canada K2H 8P9

Abstract

ABSTRACT A simple, rapid, field-adapted indirect enzyme-linked immunoassay (FldELISA) for the detection of antibodies to Brucella abortus in whole blood and serum has been developed. This assay detects antibodies to B. abortus in approximately 15 min or less. Over a 3-month period, this assay has consistently identified immunized and nonimmunized animals, while the percent coefficient of variation for each immunized animal has been less than 20%. As with any indirect enzyme-linked immunoassay, quality control can be established and maintained. Using defined positive and negative sera, the sensitivity and specificity of the FldELISA was 100% and 94.2%, respectively. As a model, this test can be readily extended to other disease applications that use lipopolysaccharide or other stable antigens for the detection of antibodies, such as those to Salmonella spp., Escherichia coli , or Yersinia spp.

Publisher

American Society for Microbiology

Subject

Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy

Reference21 articles.

1. Angus, R. D., and C. E. Barton. 1984. The production and evaluation of a buffered plate antigen for use in a presumptive test for brucellosis. Dev. Biol. Standard.56:349-356.

2. Chand, P., J. R. Sadana, H. V. Batra, and R. N. Kanna. 1989. Comparison of a dot enzyme-linked immunosorbent assay (dot-ELISA) with other serological tests for the detection of Brucella antibodies in bovine sera. Zentralbl. Veterinarmed. B.36:346-352.

3. Frey, A., B. Meckelein, D. Externest, and M. A. Schmidt. 2000. A stable and highly sensitive 3, 3′, 5, 5′-tetramethylbenzidine-based substrate reagent for enzyme-linked immunosorbent assays. J. Immunol. Methods233:47-56.

4. Gall, D., and K. Nielsen. 2002. Quality control of serological tests and applications to ISO standards 9001:2000 and 17025: examples using the fluorescence polarization assay. J. GXP Compliance6:41-47.

5. Gall, D., and K. Nielsen. 2003. A technology transfer scheme for the successful transfer and implementation of serological tests. J. GXP Compliance7:56-66.

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3