Affiliation:
1. Department of Pathology, School of Medicine,1 and
2. Institute of Human Virology,2 University of Maryland, Baltimore, Maryland;
3. Medical Research Foundation of Trinidad and Tobago, Port of Spain, Trinidad,3 and
4. Princess Margaret Hospital, Nassau, Bahamas4
Abstract
ABSTRACT
The VIDAS HIV DUO Ultra, a fourth-generation immunoassay under development for the simultaneous detection of human immunodeficiency virus type 1 (HIV-1) p24 antigen and antibodies to HIV-1 and HIV-2, was evaluated. The enzyme-linked fluorescence immunoassay, performed on the automated VIDAS instrument, is claimed to detect early and established HIV infection. The assay was challenged with a total of 2,847 samples that included 74 members of 10 seroconversion panels, 9 p24 antigen-only-reactive members of a panel of group M clades, 503 consecutively collected samples from individuals seeking care in the University of Maryland Medical System, 1,010 samples from U.S. blood donors, 1,141 samples from patients in a high-incidence population in Trinidad, 83 samples from a clinic for sexually transmitted diseases in the Bahamas, 10 confirmed HIV-1 group O samples, and 16 confirmed HIV-2 samples from the Cote d'Ivoire. Reference tests were U.S. Food and Drug Administration-licensed HIV antibody screening, p24 antigen tests, HIV confirmatory assays, and the Roche Diagnostics Amplicor HIV-1 Monitor. The VIDAS HIV DUO Ultra demonstrated 100% sensitivity and 99.5% specificity overall, with a 99.7% specificity in low-risk individuals. The analytical sensitivity, as assessed by seroconversion panels and p24 antigen in samples, was equivalent to the sensitivity of the reference assays used to characterize these panels. The VIDAS HIV DUO Ultra is accurate, offers potential advantages over conventional HIV testing for time and cost savings, has walk-away capability, and correctly identifies both early and established HIV infections.
Publisher
American Society for Microbiology
Reference27 articles.
1. VIDAS Immunoassay System;Alpert N. L.;Clin. Instrum. Syst.,1993
2. Constantine
N. T.
Supplemental tests for HIV-1 infection
Retrovirology and retroviral testing.
Constantine
N. T.
Callahan
J. D.
Watts
D. M.
1992
59
85
CRC Press Inc.
Boca Raton Fla
3. Sensitivity of HIV antibody assays as determined by seroconversion panels;Constantine N. T.;AIDS,1994
4. Diagnostic challenges for rapid human immunodeficiency virus assays. Performance using HIV-1 group O, HIV-1 group M, and HIV-2 samples;Constantine N. T.;J. Hum. Virol.,1997
5. Constantine
N. T.
HIV antibody testing
The AIDS knowledge base
3rd ed.
Cohen
P. T.
Sande
M. A.
Volberding
P. A.
1999
105
112
Lippincott-Williams & Wilkins
Philadelphia Pa
Cited by
63 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献