Multicenter Evaluation of a New, Automated Enzyme-Linked Immunoassay for Detection of Human Immunodeficiency Virus-Specific Antibodies and Antigen

Author:

Sickinger Eva1,Stieler Myriam1,Kaufman Boris1,Kapprell Hans-Peter1,West Daniel2,Sandridge Arnold2,Devare Sushil2,Schochetman Gerald2,Hunt J. C.2,Daghfal David2

Affiliation:

1. Abbott Diagnostika GmbH & Co. KG, Wiesbaden, Germany

2. Abbott Laboratories, Abbott Park, Illinois

Abstract

ABSTRACT A collaborative multicenter study was conducted to evaluate the sensitivity, specificity, and precision of a three-step, fully automated, qualitative microparticle-based enzyme-linked immunoassay (AxSYM HIV Ag/Ab Combo; Abbott Laboratories), designed to simultaneously detect (i) antibodies against human immunodeficiency virus type 1 (HIV-1) and/or type 2 (HIV-2) and (ii) HIV p24 antigen. A significant reduction in the HIV seroconversion window was achieved by combining detection of HIV antibodies and antigen into a single assay format. For 22 selected, commercial HIV seroconversion panels, the mean time of detection with the combined-format HIV antigen-antibody assay was reduced by 6.15 days compared to that with a similar third-generation single-format HIV antibody assay. The quantitative sensitivity of the combination assay for the p24 antigen (17.5 pg/ml by use of the p24 quantitative panel VIH SFTS96′) was nearly equivalent to that of single-format antigen tests. The combination assay demonstrated sensitive (100%) detection of anti-HIV immunoglobulin in specimens from individuals in CDC stages A, B, and C and from individuals infected with different HIV-1 group M subtypes, group O, or HIV-2. The apparent specificity for hospitalized patients ( n = 1,938) was 99.90%. In a random population of 7,900 volunteer blood donors, the specificity (99.87%) was comparable to that of a third-generation single-format HIV antibody assay (99.92%) on the same donor specimens. In addition, the combination assay was robust to potential interfering specimens. The precision of the combination was high, with intra- and interrun variances of ≤9.3% for each precision panel specimen or assay control and ≤5.3% for the negative assay control.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3