Marine Bacteria Cause False-Positive Results in the Colilert-18 Rapid Identification Test for Escherichia coli in Florida Waters

Author:

Pisciotta John M.1,Rath Damon F.2,Stanek Paul A.2,Flanery D. Michael2,Harwood Valerie J.1

Affiliation:

1. Department of Biology, University of South Florida, Tampa, Florida 33620-5150

2. Pinellas County Health Department, Florida Department of Health, Clearwater, Florida 33764

Abstract

ABSTRACT The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-18) frequently exceeded fecal coliform counts (by membrane filtration) by 1 to 3 orders of magnitude. Samples from freshwater sites did not display similar discrepancies. Fecal coliforms, including E. coli , could be cultured from 100% of yellow fluorescent wells (denoting E. coli -positive results) inoculated with freshwater samples but could be cultured from only 17.1% of the “positive” wells inoculated with marine samples. Ortho -nitrophenyl-β- d -galactopyranoside (ONPG)-positive or 4-methylumbelliferyl-β- d -glucuronide (MUG)-positive noncoliform bacteria were readily cultured from Colilert-18 test wells inoculated with marine samples. Filtered cell-free seawater did not cause false positives. Coculture preparations of as few as 5 CFU of Vibrio cholerae (ONPG positive) and Providencia sp. (MUG positive) ml −1 inoculated into Colilert-18 caused false-positive E. coli results. Salinity conditions influenced coculture results, as the concentration of coculture inoculum required to cause false positives in most wells increased from about 5 CFU ml −1 in seawater diluted 1:10 with freshwater to ≈5,000 CFU ml −1 in seawater diluted 1:20 with freshwater. Estimated E. coli numbers in various marine water samples processed at the 1:10 dilution ranged from 10 to 7,270 CFU·100 ml −1 , while E. coli numbers in the same samples processed at the 1:20 dilution did not exceed 40 CFU·100 ml −1 . The lower estimates of E. coli numbers corresponded well with fecal coliform counts by membrane filtration. This study indicates that assessment of E. coli in subtropical marine waters by Colilert-18 is not accurate when the recommended 1:10 sample dilution is used. The results suggest that greater dilution may diminish the false-positive problem, but further study of this possibility is recommended.

Publisher

American Society for Microbiology

Subject

Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology

Reference23 articles.

1. Chang, G. W., J. Brill, and R. Lum. 1989. Proportion of β-d-glucuronidase-negative Escherichia coli in human fecal samples. Appl. Environ. Microbiol.56:335-339.

2. Evaluation of the Autoanalysis Colilert test for detection and enumeration of total coliforms

3. Covert, T. C., E. W. Rice, S. A. Johnson, D. Berman, C. H. Johnson, and P. J. Mason. 1992. Comparing defined-substrate coliform tests for the detection of Escherichia coli in water. J. Am. Water Works Assoc.84:98-104.

4. Plant and algal interference in bacterial beta-D-galactosidase and beta-D-glucuronidase assays

5. Davies, C. M., S. C. Apte, S. M. Peterson, and J. L. Stauber. 1995. Possible interference of lactose-fermenting marine vibrios in coliform β-d-galatosidase assays. J. Appl. Bacteriol.78:287-393.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3