Validation of a Multiplex Pneumococcal Serotyping Assay with Clinical Samples

Author:

Lin Jisheng1,Kaltoft Margit S.2,Brandao Angela P.34,Echaniz-Aviles Gabriela5,Brandileone M. Cristina C.3,Hollingshead Susan K.6,Benjamin William H.16,Nahm Moon H.16

Affiliation:

1. Department of Pathology, University of Alabama at Birmingham, Birmingham, Alabama

2. The WHO Collaborating Center for Reference and Research on Pneumococci, Statens Serum Institut, Copenhagen, Denmark

3. Bacteriology Section, Adolfo Lutz Institute, Sao Paulo, Brazil

4. IOC/FIOCRUZ, Rio de Janeiro, Brazil

5. Department of Clinical Epidemiology, National Institute of Public Health, Cuernavaca, Mexico

6. Department of Microbiology, University of Alabama at Birmingham, Birmingham, Alabama

Abstract

ABSTRACT We have recently developed a rapid pneumococcal serotyping method called “multibead assay” (J. Yu et al., J. Clin. Microbiol. 43: 156-162, 2005) based on a multiplexed immunoassay for capsular polysaccharides in lysates of pneumococcal cultures. The multibead assay can identify 36 serotypes (1, 2, 3, 4, 5, 6A, 6B, 7A/7F, 8, 9L/9N, 9V, 10A/10B/39/33C, 11A/11D/11F, 12A/12B/12F, 14, 15B/5C, 17F, 18C, 19A, 19F, 20, 22A/22F, 23F, and 33A/33F). More than 90% of the U.S. isolates express one of these serotypes (J. B. Robbins et al., J. Infect. Dis. 148: 1136-1159, 1983). To validate the new assay, we examined 495 clinical isolates of pneumococci obtained in Brazil, Denmark, and Mexico. Pneumococci were serotyped by the Neufeld test in their countries of origin, and lysates of each strain were coded and mailed to the United States for the multibead assay at ambient temperature without any thermal protection. After breaking the code, 54 discrepancies (11% of samples) were noted, but 46 were due to nonreproducible technical problems or insufficient growth of the pneumococci. All of the isolates grew well for a second test, and therefore, the culture medium used for the multibead assay is adequate. The discrepancies persisted for eight isolates, involving the 6A, 11A, and 18C serotypes. Additional studies of the eight isolates showed that the discrepancies were due to differences in the reagents used in the multibead or Neufeld tests for these three serotypes. For instance, five isolates were typed as 6A with the Neufeld test but as nontypeable by the multibead assay. Selection of another new monoclonal antibody (Hyp6AG1) for the multibead assay resulted in all five discrepant isolates typing as 6A. This finding indicates the validity of the multibead assay and emphasizes the need to validate any new pneumococcal serotyping assay with a large number of clinical isolates from different locations. It also suggests the presence of serological subtypes among isolates expressing the 6A serotype.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3