Affiliation:
1. Pharma Research Center, Institute of Clinical Pharmacology, Bayer AG, 42096 Wuppertal, Germany
Abstract
ABSTRACT
The pharmacokinetics of moxifloxacin were investigated in six studies after oral administration of 50, 100, 200, 400, 600, and 800 mg. Eight healthy male volunteers were included in each study. With doses of up to 200 mg the study was performed as a double-blind, randomized group comparison (
n
= 6 verum and
n
= 2 matched placebo); with the higher doses the study was conducted with a double-blind, randomized, crossover design. Safety and tolerability were assessed by evaluation of vital signs, electrocardiograms, electroencephalograms, clinical chemistry parameters, results of urinalysis, and adverse events. The drug was well tolerated. The concentrations of moxifloxacin in plasma, urine, and saliva were determined by a validated high-pressure liquid chromatography assay with fluorescence detection. In addition, plasma and urine samples were analyzed by a bioassay. A good correlation between both methods was seen, indicating an absence of major active metabolites. The mean maximum concentrations of moxifloxacin in plasma (
C
max
) ranged from 0.29 mg/liter (50-mg dose) to 4.73 mg/liter (800-mg dose) and were reached 0.5 to 4 h following drug administration. After reaching the
C
max
, plasma moxifloxacin concentrations declined in a biphasic manner. Within 4 to 5 h they fell to about 30 to 55% of the
C
max
, and thereafter a terminal half-life of 11 to 14 h accounted for the major part of the area under the concentration-time curve (AUC). During the absorption phase concentrations in saliva were even higher than those in plasma, whereas in the terminal phase a constant ratio of the concentration in saliva/concentration in plasma of between 0.5 and 1 was observed, indicating a correlation between unbound concentrations in plasma and levels in saliva (protein binding level, approximately 48%). AUC and
C
max
increased proportionally to the dose over the whole range of doses investigated. Urinary excretion amounted to approximately 20% of the dose. Data on renal clearance (40 to 51 ml/min/1.73 m
2
) indicated partial tubular reabsorption of the drug. The pharmacokinetic parameters derived from compartmental and noncompartmental analyses were in good agreement. The kinetics could be described best by fitting the data to a two-compartment body model.
Publisher
American Society for Microbiology
Subject
Infectious Diseases,Pharmacology (medical),Pharmacology
Reference17 articles.
1. Pharmacokinetics of ciprofloxacin after oral and intravenous administration.;Borner K.;Eur. J. Clin. Microbiol.,1986
2. In vitro activity of BAY 12-8039, a new 8-methoxyquinolone.;Dalhoff A.;Chemotherapy (Basel),1996
3. Domdey-Bette A. (Bayer AG). 1996. Private communication.
4. Gibaldi
M.
Perrier
D.
Pharmacokinetics.
1982
Marcel Dekker Inc.
New York N.Y
5. Heinzel
G.
Woloszczak
R.
Thomann
P.
Topfit 2.0 pharmacokinetic and pharmacodynamic data analysis system for the PC.
1993
Gustav Fischer
Stuttgart Germany
Cited by
274 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献