Author:
Armstrong J L,Calomiris J J,Seidler R J
Abstract
Standard plate count (SPC) bacteria were isolated from a drinking-water treatment facility and from the river supplying the facility. All isolates were identified and tested for their resistance to six antibiotics to determine if drug-resistant bacteria were selected for as a consequence of water treatment. Among the isolates surviving our test procedures, there was a significant selection (P less than 0.05) of gram-negative SPC organisms resistant to two or more of the test antibiotics. These bacteria were isolated from the flash mix tank, where chlorine, alum, and lime are added to the water. Streptomycin resistance in particular was more frequent in this population as compared with bacteria in the untreated river water (P less than 0.01). SPC bacteria from the clear well, which is a tank holding the finished drinking water at the treatment facility, were also more frequently antibiotic resistant than were the respective river water populations. When 15.8 and 18.2% of the river water bacteria were multiply antibiotic resistant, 57.1 and 43.5%, respectively, of the SPC bacteria in the clear well were multiply antibiotic resistant. Selection for bacteria exhibiting resistance to streptomycin was achieved by chlorinating river water in the laboratory. We concluded that the selective factors operating in the aquatic environment of a water treatment facility can act to increase the proportion of antibiotic-resistant members of the SPC bacterial population in treated drinking water.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference20 articles.
1. The occurrence of microorganisms in water main encrustaceans;Allen M.;J. Am. Water Works Assoc.,1980
2. American Public Health Association. 1980. Standard methods for the examination of water and wastewater 15th ed. American Public Health Association Inc. New York.
3. Antibiotic-resistant bacteria in drinking water;Armstrong J. L.;Appl. Environ. Microbiol.,1981
4. Earnhardt K. B. Jr. 1981. Chlorine resistant coliformthe Muncie Indiana experience p. 371-376. In American Water Works Association Water Quality Technology Conference Proceedings Advances in Laboratory Techniques for Quality Control. American Water Works Association Denver Colorado.
5. The necessity of controlling bacterial populations in potable waters: community water supply;Geldreich E. E.;J. Am. Water Works Assoc.,1972